Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).
Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).
Get tips on using ShRNA CD24 Lentiviral Transduction Particles (CD24-V2LHS_71909)) to perform shRNA gene silencing Mouse - Prostate cancer cell lines (DU145 and PC3) CD24 lentiviral particles
Get tips on using ShRNA CD24 Lentiviral Transduction Particles (CD24-V2LHS_71908) to perform shRNA gene silencing Mouse - Prostate cancer cell lines (DU145 and PC3) CD24 lentiviral particles
Get tips on using Cdc42 Polyclonal Antibody to perform Western blotting Cdc42
Get tips on using Mouse/Rat CD34 Antibody to perform Immunohistochemistry Mouse - CD34
Get tips on using Biotin Rat Anti-Mouse CD24 to perform Immunohistochemistry Mouse - CD24
Get tips on using CD24 Antibody (M1/69): sc-19651 to perform Immunohistochemistry Mouse - CD24
Get tips on using Recombinant Anti-CD34 antibody [EP373Y] (ab81289) to perform Immunohistochemistry Mouse - CD34
Get tips on using CD34 Antibody (MEC 14.7): sc-18917 to perform Immunohistochemistry Mouse - CD34
Fill out your contact details and receive price quotes in your Inbox
Outsource experiment