RNA quantification for appropriate concentration and quality (260/280 ratio) is an important step before downstream analysis (including sequencing, RT-qPCR, etc.). Having insufficient RNA quantities or a high salt or phenol in the RNA product can lead to variable or irreproducible downstream results. The various methods used for RNA quantification include: 1. UV spectrophotometric (challenges include: low sensitivity, cannot distinguish between nucleic acid species), 2. Fluorescence-based (challenges include: requires standards, cannot measure amplifiability, not sequence-specific), and 3. RT-PCR (challenges include: requires standards, time-intensive, costly). In order to overcome these challenges, and also to ensure the proper quantification and quality control for RNA product, it is important to use at least two or more methods in order to discard any inconsistencies. Using standards for calibrations increases the sensitivity range for RNA detention (fluorescence- and RT-PCR-based methods). When using RT- PCR, it is important to choose correct primers, aligning to the desired site on the template and of appropriate product length, along with positive, negative and loading controls. It is also important to have at least two primer pairs in order to confirm results.
RNA quantification for appropriate concentration and quality (260/280 ratio) is an important step before downstream analysis (including sequencing, RT-qPCR, etc.). Having insufficient RNA quantities or a high salt or phenol in the RNA product can lead to variable or irreproducible downstream results. The various methods used for RNA quantification include: 1. UV spectrophotometric (challenges include: low sensitivity, cannot distinguish between nucleic acid species), 2. Fluorescence-based (challenges include: requires standards, cannot measure amplifiability, not sequence-specific), and 3. RT-PCR (challenges include: requires standards, time-intensive, costly). In order to overcome these challenges, and also to ensure the proper quantification and quality control for RNA product, it is important to use at least two or more methods in order to discard any inconsistencies. Using standards for calibrations increases the sensitivity range for RNA detention (fluorescence- and RT-PCR-based methods). When using RT- PCR, it is important to choose correct primers, aligning to the desired site on the template and of appropriate product length, along with positive, negative and loading controls. It is also important to have at least two primer pairs in order to confirm results.
Get tips on using Dynabeads™ Untouched™ Human T Cells Kit to perform Cell Isolation Human T cells
Get tips on using Qubit RNA HS Assay Kit to perform RNA quantification Fuorimetric - human trophoblast cells
Get tips on using AllPrep DNA/RNA/Protein Mini Kit to perform Protein isolation Tissue - Human placental tissue
Get tips on using Silencer® Select GLO-1 siRNA to perform siRNA / miRNA gene silencing Human - Primary Human Aortic Endothelial Cells GLO-1 Lipid
Get tips on using TruSeq RNA Library Prep Kit v2 to perform RNA sequencing Rat - Retinal ganglion cells (RGCs)
Get tips on using Quant-iT™ RNA Assay Kit to perform RNA quantification Fuorimetric - mouse glial cells
A PCR reaction consists of the template DNA, two primers covering the amplification site, an enzyme, and buffers. The resulting amplicons are generally detected by gel electrophoresis and for some further applications like cloning, sequencing, amplicon product needs to be recovered from the gel and subsequently purified. However, non-specific product amplification and primer-dimer formation during set-up make gel extraction difficult. Nevertheless, high-quality DNA polymerase and optimize reaction buffers will certainly lead to a successful PCR reaction.
A PCR reaction consists of the template DNA, two primers covering the amplification site, an enzyme, and buffers. The resulting amplicons are generally detected by gel electrophoresis and for some further applications like cloning, sequencing, amplicon product needs to be recovered from the gel and subsequently purified. However, non-specific product amplification and primer-dimer formation during set-up make gel extraction difficult. Nevertheless, high-quality DNA polymerase and optimize reaction buffers will certainly lead to a successful PCR reaction.
Fill out your contact details and receive price quotes in your Inbox
Outsource experiment