cell-cycle-assay-human-hela

- Found 8599 results

As autophagy is a multi-step process which includes not just the formation of autophagosomes, but most importantly, flux through the entire system, including the degradation upon fusion with lysosomes, which makes it quite challenging for detection. There are several methods for detection in mammalian cells, including immunoblotting analysis of LC3 and p62 and detection of autophagosome formation/maturation by fluorescence microscopy, Currently, there is no single “gold standard” for determining the autophagic activity that is applicable in every experimental context, hence it is recommended to go for the combined use of multiple methods to accurately assess the autophagic activity in any given biological setting.

Cellular assays Autophagy assay cell type CLL

Get tips on using CometAssay Single Cell Gel Electrophoresis Assay-Silver to perform DNA Damage Assay HCT 116

Products Bio-Techne CometAssay Single Cell Gel Electrophoresis Assay-Silver

Get tips on using CometAssay Single Cell Gel Electrophoresis Assay-Silver to perform DNA Damage Assay DLD-1

Products Bio-Techne CometAssay Single Cell Gel Electrophoresis Assay-Silver

Get tips on using CometAssay Single Cell Gel Electrophoresis Assay-Silver to perform DNA Damage Assay Caco-2

Products Bio-Techne CometAssay Single Cell Gel Electrophoresis Assay-Silver

Get tips on using CyQUANT® Cell Proliferation Assay Kit to perform AAA for reviews

Products Thermo Fisher Scientific CyQUANT® Cell Proliferation Assay Kit

A gross majority of classical apoptotic attributes can be quantitatively examined by flow cytometry, the preferred platform for rapid assessment of multiple cellular attributes at a single-cell level. However, sample preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Apoptosis assay cell type Array of apoptotic proteins

A gross majority of classical apoptotic attributes can be quantitatively examined by flow cytometry, the preferred platform for rapid assessment of multiple cellular attributes at a single-cell level. However, sample preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Apoptosis assay cell type Sao2-2, MG-62

Get tips on using RealTime-Glo™ MT Cell Viability Assay to perform Live / Dead assay mammalian cells - INS-1 832/12

Products Promega RealTime-Glo™ MT Cell Viability Assay

Get tips on using Cultrex BME Cell Invasion Assay, 96 well to perform Cell migration / Invasion cell type - AGS

Products R&D Systems Cultrex BME Cell Invasion Assay, 96 well

Get tips on using 96-Well Cell Invasion Assay, Basement Membrane to perform Cell migration / Invasion cell type - OE33

Products Cell Biolabs 96-Well Cell Invasion Assay, Basement Membrane

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms