Select Host / Primary antibody raised in


Flowcytometry CD16

- Found 213 results

Get tips on using Alexa Fluor 700-labeled anti-CD16 to perform Flowcytometry CD16 - Mouse /IgG1, kappa Human Alexa Fluor 700

Products BioLegend Alexa Fluor 700-labeled anti-CD16

Get tips on using InVivoMAb anti-mouse CD16/CD32 to perform Flow cytometry Anti-bodies Mouse - CD16/CD32

Products Bio X Cell InVivoMAb anti-mouse CD16/CD32

Cellular assays Cell Isolation CD16+ Monocyte

Cellular assays Cell Isolation CD56+CD16+ NK Cell

Get tips on using Purified Rat Anti-Mouse CD16/CD32 (Mouse BD Fc Block™) to perform Flow cytometry Anti-bodies Mouse - CD16/CD32

Products BD Biosciences Purified Rat Anti-Mouse CD16/CD32 (Mouse BD Fc Block™)

Get tips on using EasySep™ Human Monocyte Enrichment Kit without CD16 Depletion to perform Cell Isolation Monocyte

Products STEMCELL technologies EasySep™ Human Monocyte Enrichment Kit without CD16 Depletion

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse CD16/CD32

Get tips on using CD14 Antibody, Pacific Orange™ conjugate to perform Flowcytometry CD14 - Mouse / IgG2a Human Pacific Orange™

Products Thermo Fisher Scientific CD14 Antibody, Pacific Orange™ conjugate

Get tips on using Anti-Human CD56 (NCAM) APC-eFluor® 780 to perform Flowcytometry CD56 (NCAM) - Mouse / IgG1, kappa Human APC-eFluor 780

Products eBioscience Anti-Human CD56 (NCAM) APC-eFluor® 780

Get tips on using Anti-Human CD282 (TLR2) FITC to perform Flowcytometry TLR2 (CD282) - Mouse / IgG1, kappa Human FITC

Products eBioscience Anti-Human CD282 (TLR2) FITC

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms