ELISA Mouse

- Found 2148 results

Site-directed mutagenesis (SDM) can be challenging, particularly during detection/confirmation of (SDM) in colonies by sequencing or PCR techniques. This common issue in SDM is heavily relying on designing of mutagenic primer pairs. The best solution is to design the mutagenic primers that have extended 3'-ends/3'-overhang. This would provide the annealing region between the mutagenic primer pair is essentially shorter. and hence ensure a lower annealing temperature for the primer pair along with a higher chance of annealing to the template.

DNA Site Directed Mutagenesis (SDM) Mouse Point mutation L929 SigmaR1 gene (σ1)

Get tips on using Monoclonal Anti-MAP Kinase, Activated/monophosphorylated (Phosphothreonine ERK-1&2) antibody produced in mouse to perform Western blotting ERK

Products Sigma-Aldrich Monoclonal Anti-MAP Kinase, Activated/monophosphorylated (Phosphothreonine ERK-1&2) antibody produced in mouse

RNA siRNA / miRNA gene silencing Mouse Glomerular mesangial cells HIPK2 Polymer / Lipid delivery

Site-directed mutagenesis (SDM) can be challenging, particularly during detection/confirmation of (SDM) in colonies by sequencing or PCR techniques. This common issue in SDM is heavily relying on designing of mutagenic primer pairs. The best solution is to design the mutagenic primers that have extended 3'-ends/3'-overhang. This would provide the annealing region between the mutagenic primer pair is essentially shorter. and hence ensure a lower annealing temperature for the primer pair along with a higher chance of annealing to the template.

DNA Site Directed Mutagenesis (SDM) Mouse Point mutation 3T3-L1 S6 kinase 1

Get tips on using Multi-Analyte ELISArray Kits to perform ELISA Human - GM-CSF

Products Qiagen Multi-Analyte ELISArray Kits

Short hairpin or small hairpin RNA (shRNA) is artificial RNA, which has a hairpin loop structure, and uses inherent microRNA (miRNA) machinery to silence target gene expression. This is called RNA interference (RNAi). These can be delivered via plasmids or viral/bacterial vectors. Challenges in shRNA-mediated gene silencing include: 1. Off-target silencing, 2. Packaging shRNA encoding lentivirus, and 3. Stable transduction in cells. RNAi have been designed to have anywhere from 19-27 bs, but the most effective design has 19 bp. In case commercial shRNAs are not available, potential target sites can be chosen within exon, 5’- or 3’ UTR, depending on which splice variants of the gene are desired. One should use the latest algorithms and choose at least two different sequences, targeting different regions, in order to have confidence in overcoming off-target effects. A BLAST search after selecting potential design will eliminate potential off-target sequences. For the second challenge, sequencing the vector using primers for either strand (50-100 bp upstream) is suggested, along with using enzymatic digestion on agarose gel for the vector. Next, once the shRNA-containing vector is packaged in a virus, it is important to check the viral titer before transduction. Finally, using a marker in the lentiviral vector (fluorescent protein or antibiotic resistance), along with qPCR for target gene expression can help in determining efficacy of transduction and shRNA on its target site.

RNA shRNA gene silencing Mouse Prostate cancer cell lines (DU145 and PC3) CD24 lentiviral particles

Get tips on using Rat Gastrin EIA to perform ELISA Rat - Gastrin

Products Raybiotech Rat Gastrin EIA

Get tips on using Human ANGPTL3 (highly sensitive) Assay Kit (27750 ) to perform ELISA Human - Angiopoietin-Like 3 (AngptL3)

Products IBL, Immuno-Biological Laboratories co,Ltd Human ANGPTL3 (highly sensitive) Assay Kit (27750 )

Get tips on using MicroVue YKL-40 EIA to perform ELISA Human - Chitinase-3-Like Protein-1 (CHI3L1) or YKL-40

Products Quidel MicroVue YKL-40 EIA

Get tips on using ProcartaPlex Human Cytokine Panel 1B, 25 plex to perform ELISA (kit) Human Serum Cytokine measurements (Multiplex assay) - -NA- Human -NA-

Products eBioscience ProcartaPlex Human Cytokine Panel 1B, 25 plex

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms