siRNA / RNAi /miRNA transfection Human Cells KG-1

- Found 9625 results

Cell Invasion or Cell Migration assays are technically challenging to set up as the gradient between the two compartments equilibrates in time during the assay. It is also problematic to view cells and for cells to migrate through a non-physiologic polycarbonate or polypropylene filter. Care must be taken while loading the well with cells to form a single cell suspension. Precaution must be taken while trypsinization (under-trypsinization can lead to cell clumping while over-trypsinization could strip off adhesion molecules necessary for migration). This leads to difficulty in getting significant results, when only small numbers of cells cross the filter or when the distribution and/or staining of the cells is uneven.

Cellular assays Cell migration / Invasion cell type SK-MEL-1

A gross majority of classical apoptotic attributes can be quantitatively examined by flow cytometry, the preferred platform for rapid assessment of multiple cellular attributes at a single-cell level. However, sample preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Apoptosis assay cell type PANC-1

A gross majority of classical apoptotic attributes can be quantitatively examined by flow cytometry, the preferred platform for rapid assessment of multiple cellular attributes at a single-cell level. However, sample preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Apoptosis assay cell type THP-1

A gross majority of classical apoptotic attributes can be quantitatively examined by flow cytometry, the preferred platform for rapid assessment of multiple cellular attributes at a single-cell level. However, sample preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Apoptosis assay cell type OECM-1

A gross majority of classical apoptotic attributes can be quantitatively examined by flow cytometry, the preferred platform for rapid assessment of multiple cellular attributes at a single-cell level. However, sample preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Apoptosis assay cell type PA-1

Get tips on using mirVana™ miRNA Isolation Kit, with phenol to perform RNA isolation / purification Bacteria - Gram positive Staphylococcus saprophycitius

Products Thermo Fisher Scientific mirVana™ miRNA Isolation Kit, with phenol

Get tips on using mirVana™ miRNA Isolation Kit, with phenol to perform RNA isolation / purification Bacteria - Gram negative Klebsiella pneumoniae

Products Thermo Fisher Scientific mirVana™ miRNA Isolation Kit, with phenol

Get tips on using mirVana™ miRNA Isolation Kit, with phenol to perform RNA isolation / purification Bacteria - Gram negative Salmonella enterica

Products Thermo Fisher Scientific mirVana™ miRNA Isolation Kit, with phenol

The RNA-guided CRISPR-Cas9 nuclease system has revolutionized the genome editing practices. For the most part, the Cas9-mediated genome editing is performed either via nonhomologous end joining (NHEJ) or homology-directed repair (HDR) in mammalian cells, However, designing of specific sgRNAs and minimizing off-target cleavage mediated mutagenesis are the major challenges in CRISPR-Cas based genome editing. To circumvent these issues, we can take advantages of many available tools and approaches for sgRNA construction and delivery.

DNA CRISPR Rat Deletion INS-1 832/13 Ep300

Get tips on using Anti-Beclin 1 antibody (ab62557) to perform Autophagy assay cell type - RSC96

Products Abcam Anti-Beclin 1 antibody (ab62557)

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms