Select a Cell type


DNA quantification Mouse

- Found 4558 results

miRNA is the inherent gene silencing machinery which can have more than one mRNA target, whereas siRNA can be designed to target a particular mRNA target. By design, both siRNA and miRNA are 20-25 nucleotides in length. The target sequence for siRNAs is usually located within the open reading frame, between 50 and 100 nucleotides downstream of the start codon. There are two ways in which cells can be transfected with desired RNAi: 1. Direct transfection (with calcium phosphate co-precipitation or cationic lipid mediated transfection using lipofectamine or oligofectamine), and 2. Making RNAi lentiviral constructs (followed by transformation and transduction). Lentiviral constructs are time consuming, but provide a more permanent expression of RNAi in the cells, and consistent gene silencing. Direct transfection of oligonucleotides provides temporary genetic suppression. Traditional methods like calcium phosphate co-precipitation have challenges like low efficiency, poor reproducibility and cell toxicity. Whereas, cationic lipid-based transfection reagents are able to overcome these challenges, along with applicability to a large variety of eukaryotic cell lines. When using oligos, the ideal concentration lies between 10-50nM for effective transfection.

RNA siRNA / miRNA gene silencing Mouse 3T3-SA Zbp1/Dai

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse Ly-6A-E/Sca1

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse Ly6C/Gr-1/Ly6G

Get tips on using Monoclonal Mouse Anti-Human Ki-67 Antigen (Concentrate) Clone MIB-1 to perform Immunohistochemistry Human - Ki-67

Products Agilent Technologies Monoclonal Mouse Anti-Human Ki-67 Antigen (Concentrate) Clone MIB-1

Get tips on using Purified Mouse Anti-Human ZO-1 Clone 1/ZO-1 (RUO) to perform Western blotting ZO-1

Products BD Biosciences Purified Mouse Anti-Human ZO-1 Clone 1/ZO-1 (RUO)

Get tips on using BRCA2 rtu elisa kit :: Mouse Breast Cancer Susceptibility Protein 2 (BRCA2) RTU ELISA Kit to perform ELISA Mouse - BRCA2

Products MyBioSource.com BRCA2 rtu elisa kit :: Mouse Breast Cancer Susceptibility Protein 2 (BRCA2) RTU ELISA Kit

An alternative to culture-based cell death detection is an assessment of other cell viability indicators using fluorescent dyes, including membrane potential and membrane integrity. Live/Dead assays differentiates live and dead cells using membrane integrity as a proxy for cell viability and are based on a fluorescent staining procedure followed by detection using flow cytometry. However, samples preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Live / Dead assay mammalian cells mouse bone marrow-derived macrophages

Get tips on using GenLadder 100 bp + 1.5 kbp (ready-to-use), DNA marker to perform DNA Ladder 100 bp

Products Genaxxon bioscience GenLadder 100 bp + 1.5 kbp (ready-to-use), DNA marker

Get tips on using EpiTect Bisulfite Kit to perform DNA methylation profiling Whole genome profiling - mouse primordial germ cells

Products Qiagen EpiTect Bisulfite Kit

Get tips on using AmpliTaq Gold™ DNA Polymerase with Buffer II and MgCl2 to perform PCR Multiplex PCR - Mammalian DNA

Products Thermo Fisher Scientific AmpliTaq Gold™ DNA Polymerase with Buffer II and MgCl2

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms