An alternative to culture-based cell death detection is an assessment of other cell viability indicators using fluorescent dyes, including membrane potential and membrane integrity. Live/Dead assays differentiates live and dead cells using membrane integrity as a proxy for cell viability and are based on a fluorescent staining procedure followed by detection using flow cytometry. However, samples preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.
Get tips on using AMPIPROBE® Candida 1 Assay Kit to perform Cell Culture Contamination Detection Kit Yeast
Get tips on using Hop Antibody (E-1): sc-398703 to perform Flow cytometry Anti-bodies Mouse - HOPX
Get tips on using Recombinant Anti-p27 KIP 1 antibody [EPFHCR16] (ab92741) to perform Western blotting CDKN1B
Get tips on using Recombinant Anti-Integrin beta 1 antibody [EPR16895] (ab179471) to perform Western blotting ITGB1
Get tips on using Rock-2 siRNA and shRNA Plasmids (h) to perform RNA sequencing Human - HT-1376 (urinary bladder cell line)
Get tips on using miRNA Complete Labeling and Hyb Kit to perform Microarray RNA amplification & Labeling - Human endometrial stromal cells Cyanine 3-pCp
ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.
ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.
Get tips on using WST-1 Cell Proliferation Assay Kit to perform Cell cytotoxicity / Proliferation assay cell type - MG-63
Fill out your contact details and receive price quotes in your Inbox
Outsource experiment