Flowcytometry CD14 Mouse / IgG2a

- Found 1980 results

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Human CD14

Protein isolation is a technique that involves isolation and/ or purification of protein from cells or tissues via chromatography or electrophoresis. The major challenges in protein isolation include: 1. The concentration of proteins in cells is variable and tends to be small for some intracellular proteins. Unlike nucleic acids, proteins cannot be amplified. 2. Proteins are more unstable than nucleic acids. They are easily denatured under suboptimal temperature, pH or salt concentrations. 3. Finally, no generalized technique/protocol can be applied for protein isolation. Proteins may have different electrostatic (number of positively or negatively charged amino acids) or hydrophobic properties. Therefore, protein purification requires multiple steps depending on their charge (a negatively charged resin/column for positively charged proteins and vice-versa), dissolution (using detergents) and unlike in the case of DNA and RNA, instead of using salts, proteins should be isolated by isoelectric precipitation.

Proteins Protein isolation Mammalian cells Human CD14+ cells

When extracting nucleic acids from cell cultures, thorough homogenization of cells via vortexing in lysis buffer is very necessary. Choose the best RNA isolation method keeping in mind the downstream applications, generally, column-based isolations result in clean and concentrated RNA samples. Downstream applications like sequencing and cDNA synthesis require high-quality RNA, always treat the samples with DNases and check their integrity by running a gel.

RNA RNA isolation / purification Cells primary human CD14+ monocytes

Get tips on using Alexa Fluor 700-labeled anti-CD16 to perform Flowcytometry CD16 - Mouse /IgG1, kappa Human Alexa Fluor 700

Products BioLegend Alexa Fluor 700-labeled anti-CD16

Get tips on using Goat anti-Mouse IgG (H+L) Secondary Antibody, Alexa Fluor® 568 conjugate to perform Flowcytometry Secondary Antibody - Goat Mouse Alexa Fluor 568

Products Thermo Fisher Scientific Goat anti-Mouse IgG (H+L) Secondary Antibody, Alexa Fluor® 568 conjugate

Get tips on using Anti-Human CD282 (TLR2) FITC to perform Flowcytometry TLR2 (CD282) - Mouse / IgG1, kappa Human FITC

Products eBioscience Anti-Human CD282 (TLR2) FITC

Get tips on using Anti-Human CD3 PE-Cyanine7 to perform Flowcytometry CD3 - Mouse / IgG1, kappa Human PE-Cyanine7

Products eBioscience Anti-Human CD3 PE-Cyanine7

Get tips on using Anti-Human CD284 (TLR4) to perform Flowcytometry TLR4 (CD284) - Mouse / IgG1, kappa Human Brilliant violet 421

Products eBioscience Anti-Human CD284 (TLR4)

Get tips on using Anti-Human CD56 (NCAM) APC-eFluor® 780 to perform Flowcytometry CD56 (NCAM) - Mouse / IgG1, kappa Human APC-eFluor 780

Products eBioscience Anti-Human CD56 (NCAM) APC-eFluor® 780

Get tips on using Goat anti-Rabbit IgG (H+L) Secondary Antibody, Alexa Fluor® 488 conjugate to perform Flowcytometry Secondary Antibody - Goat Rabbit Alexa Fluor 488

Products Thermo Fisher Scientific Goat anti-Rabbit IgG (H+L) Secondary Antibody, Alexa Fluor® 488 conjugate