Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).
Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).
Get tips on using Purified Mouse Anti-Human MSH-2 Clone G219-1129 (RUO) to perform Immunohistochemistry Human - MSH2
Get tips on using Monoclonal Mouse Anti-Villin (Autostainer Link 48) Clone 1D2 C3 to perform Immunohistochemistry Human - Villin
Get tips on using Monoclonal Mouse Anti-Human Progesterone Receptor (Concentrate) Clone PgR 1294 to perform Immunohistochemistry Human - PR
Get tips on using Monoclonal Mouse Anti-Human CA 125 (Dako Omnis) Clone M11 to perform Immunohistochemistry Human - CA125
Get tips on using Monoclonal Mouse Anti-Human CDX2 (Dako Omnis) Clone DAK-CDX2 to perform Immunohistochemistry Human - CDX2
Get tips on using Monoclonal Anti-Proliferating Cell Nuclear Antigen antibody produced in mouse to perform Western blotting PCNA
Get tips on using Monoclonal Mouse Anti-Villin (Autostainer Link 48) Clone 1D2 C3p to perform DNA Damage Assay U266 -
Get tips on using Purified Mouse Anti-E-Cadherin Clone 36/E-Cadherin (RUO) to perform Immunohistochemistry Human - E-Cadherin
Fill out your contact details and receive price quotes in your Inbox
Outsource experiment