crispr-mouse-deletion-raw-264-7-nrp2

- Found 4626 results

Get tips on using NEBNext® Ultra™ Directional RNA Library Prep Kit for Illumina® to perform RNA sequencing Mouse - Neuro 2a

Products New England BioLabs NEBNext® Ultra™ Directional RNA Library Prep Kit for Illumina®

Get tips on using NEBNext® Ultra™ Directional RNA Library Prep Kit for Illumina® to perform RNA sequencing Mouse - BV-2

Products New England BioLabs NEBNext® Ultra™ Directional RNA Library Prep Kit for Illumina®

A gross majority of classical apoptotic attributes can be quantitatively examined by flow cytometry, the preferred platform for rapid assessment of multiple cellular attributes at a single-cell level. However, sample preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.

Cellular assays Apoptosis assay cell type SMMC-7721, HEPG2

miRNA is the inherent gene silencing machinery which can have more than one mRNA target, whereas siRNA can be designed to target a particular mRNA target. By design, both siRNA and miRNA are 20-25 nucleotides in length. The target sequence for siRNAs is usually located within the open reading frame, between 50 and 100 nucleotides downstream of the start codon. There are two ways in which cells can be transfected with desired RNAi: 1. Direct transfection (with calcium phosphate co-precipitation or cationic lipid mediated transfection using lipofectamine or oligofectamine), and 2. Making RNAi lentiviral constructs (followed by transformation and transduction). Lentiviral constructs are time consuming, but provide a more permanent expression of RNAi in the cells, and consistent gene silencing. Direct transfection of oligonucleotides provides temporary genetic suppression. Traditional methods like calcium phosphate co-precipitation have challenges like low efficiency, poor reproducibility and cell toxicity. Whereas, cationic lipid-based transfection reagents are able to overcome these challenges, along with applicability to a large variety of eukaryotic cell lines. When using oligos, the ideal concentration lies between 10-50nM for effective transfection.

RNA siRNA / miRNA gene silencing Rat NRCM Nrf2

Get tips on using GeneArt™ Site-Directed Mutagenesis System to perform Site Directed Mutagenesis (SDM) Mouse - Point mutation 3T3-L1 S6 kinase 1

Products Thermo Fisher Scientific GeneArt™ Site-Directed Mutagenesis System

Get tips on using TaqMan® MicroRNA Reverse Transcription Kit to perform siRNA / miRNA gene silencing Mouse - Glomerular mesangial cells HIPK2 Polymer / Lipid delivery

Products Thermo Fisher Scientific TaqMan® MicroRNA Reverse Transcription Kit

Get tips on using MEBMTM Mammary Epithelial Cell Growth Basal Medium to perform 3D Cell Culture Media Mouse primary breast cancer ephitelial cells-Mammospheres

Products Lonza MEBMTM Mammary Epithelial Cell Growth Basal Medium

Get tips on using GeneArt™ Site-Directed Mutagenesis PLUS System to perform Site Directed Mutagenesis (SDM) Mouse - Point mutation L929 SigmaR1 gene (σ1)

Products Thermo Fisher Scientific GeneArt™ Site-Directed Mutagenesis PLUS System

Get tips on using pSUPER.retro.neo+gfp vector- Syn G (exon 3) siRNA to perform shRNA gene silencing Mouse - RGC-5 Syn G (Exon 3)

Products Oligoengine pSUPER.retro.neo+gfp vector- Syn G (exon 3) siRNA

Get tips on using Silencer® Select Negative Control No 1 siRNA to perform siRNA / miRNA gene silencing Mouse - siRNA negative control polymer / lipid

Products Thermo Fisher Scientific Silencer® Select Negative Control No 1 siRNA

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms