shRNA gene silencing Mouse Prostate cancer cell lines (DU145 and PC3)

- Found 9733 results

Get tips on using Mouse CCL2/JE/MCP-1 Quantikine ELISA Kit to perform ELISA Mouse - MCP1

Products R&D Systems Mouse CCL2/JE/MCP-1 Quantikine ELISA Kit

Get tips on using Mouse Epidermal Growth Factor Receptor (EGFR) ELISA Kit to perform ELISA Mouse - EGFR

Products MyBioSource.com Mouse Epidermal Growth Factor Receptor (EGFR) ELISA Kit

Get tips on using MethylCap kit to perform DNA methylation profiling Whole genome profiling - HCT116, HTC15 human colon cancer cells

Products Diagenode MethylCap kit

The estimation of DNA methylation level heavily depends on the complete conversion of non-methylated DNA cytosines. It is crucial to ensure complete conversion of non-methylated cytosines in DNA. Therefore, it is important to incorporate controls for bisulfite reactions, as well as to pay attention to the appearance of cytosines in non-CpG sites after sequencing, which is an indicator of incomplete conversion.

DNA DNA methylation profiling Whole genome profiling mouse iPSCs

Get tips on using Purified anti-mouse CD274 (B7-H1, PD-L1) Antibody to perform Flow cytometry Anti-bodies Mouse - CD274/PD-L1

Products BioLegend Purified anti-mouse CD274 (B7-H1, PD-L1) Antibody

Get tips on using APC anti-mouse CD274 (B7-H1, PD-L1) Antibody to perform Flow cytometry Anti-bodies Mouse - CD274/PD-L1

Products BioLegend APC anti-mouse CD274 (B7-H1, PD-L1) Antibody

Get tips on using PE anti-mouse CD273 (B7-DC, PD-L2) Antibody to perform Flow cytometry Anti-bodies Mouse - CD273/PD-L2

Products BioLegend PE anti-mouse CD273 (B7-DC, PD-L2) Antibody

Cell cytotoxicity assays measure the ability of certain compounds or chemical mediators to reduce the viability of the cells. The term cell cytotoxicity assay can sometimes be used interchangeably with cell proliferation assay. Healthy living cells can be identified by the use of formazan dyes, protease biomarkers or by measuring ATP content. The formazan dyes are chromogenic products formed by the reduction of tetrazolium salts by dehydrogenases, such as lactate dehydrogenase (LDH) and reductases that are released during cell death. Common tetrazolium salts include INT, MTT, MTS and XTT. Cell cytotoxicity can also be measured by using the SRB and WST-1 assays. These assays can usually be used in a high-throughput fashion and can be quantitated by measuring absorbance, colorimetry or luminescence. All these assays require similar numbers of cell plating at the initiation, a time course of treatment with the cytotoxic agent and at least triplicates for each condition at every point of analysis. Cell shrinkage, plasma membrane blebbing, cell detachment, externalization of phosphatidylserine, nuclear condensation and ultimately DNA fragmentation are well-described features of apoptosis. The assays that rely on cell membrane integrity for their function, may not be able to quantify early apoptosis. Therefore, in order to distinguish early apoptotic vs. late apoptotic or necrotic cells, additional flow cytometry techniques can be used. A combination of Annexin V and PI (propidium iodide) can be used to distinguish early (Annexin V+/PI-) and late apoptotic (Annexin V+/PI+) cells. Sometimes, caspase assays are used in order to differentiate the stages of apoptosis.

Cellular assays Cell cytotoxicity / Proliferation assay cell type PC-3

Cell cytotoxicity assays measure the ability of certain compounds or chemical mediators to reduce the viability of the cells. The term cell cytotoxicity assay can sometimes be used interchangeably with cell proliferation assay. Healthy living cells can be identified by the use of formazan dyes, protease biomarkers or by measuring ATP content. The formazan dyes are chromogenic products formed by the reduction of tetrazolium salts by dehydrogenases, such as lactate dehydrogenase (LDH) and reductases that are released during cell death. Common tetrazolium salts include INT, MTT, MTS and XTT. Cell cytotoxicity can also be measured by using the SRB and WST-1 assays. These assays can usually be used in a high-throughput fashion and can be quantitated by measuring absorbance, colorimetry or luminescence. All these assays require similar numbers of cell plating at the initiation, a time course of treatment with the cytotoxic agent and at least triplicates for each condition at every point of analysis. Cell shrinkage, plasma membrane blebbing, cell detachment, externalization of phosphatidylserine, nuclear condensation and ultimately DNA fragmentation are well-described features of apoptosis. The assays that rely on cell membrane integrity for their function, may not be able to quantify early apoptosis. Therefore, in order to distinguish early apoptotic vs. late apoptotic or necrotic cells, additional flow cytometry techniques can be used. A combination of Annexin V and PI (propidium iodide) can be used to distinguish early (Annexin V+/PI-) and late apoptotic (Annexin V+/PI+) cells. Sometimes, caspase assays are used in order to differentiate the stages of apoptosis.

Cellular assays Cell cytotoxicity / Proliferation assay cell type PC-9

Proteins Immunohistochemistry Mouse CD166 / ALCAM

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms