ROS assay cell type

- Found 7339 results

Short hairpin or small hairpin RNA (shRNA) is artificial RNA, which has a hairpin loop structure, and uses inherent microRNA (miRNA) machinery to silence target gene expression. This is called RNA interference (RNAi). These can be delivered via plasmids or viral/bacterial vectors. Challenges in shRNA-mediated gene silencing include: 1. Off-target silencing, 2. Packaging shRNA encoding lentivirus, and 3. Stable transduction in cells. RNAi have been designed to have anywhere from 19-27 bs, but the most effective design has 19 bp. In case commercial shRNAs are not available, potential target sites can be chosen within exon, 5’- or 3’ UTR, depending on which splice variants of the gene are desired. One should use the latest algorithms and choose at least two different sequences, targeting different regions, in order to have confidence in overcoming off-target effects. A BLAST search after selecting potential design will eliminate potential off-target sequences. For the second challenge, sequencing the vector using primers for either strand (50-100 bp upstream) is suggested, along with using enzymatic digestion on agarose gel for the vector. Next, once the shRNA-containing vector is packaged in a virus, it is important to check the viral titer before transduction. Finally, using a marker in the lentiviral vector (fluorescent protein or antibiotic resistance), along with qPCR for target gene expression can help in determining efficacy of transduction and shRNA on its target site.

RNA shRNA gene silencing Mouse Prostate cancer cell lines (DU145 and PC3) CD24 lentiviral particles

Get tips on using Anti-Collagen III antibody (ab7778) to perform Western blotting Type III collagen

Products Abcam Anti-Collagen III antibody (ab7778)

RNA siRNA / miRNA gene silencing Human HNSCC cell line Eph receptor B4 Polymer / Lipid

Get tips on using COL3A1 Antibody (B-10): sc-271249 to perform Western blotting Type III collagen

Products Santa Cruz Biotechnology COL3A1 Antibody (B-10): sc-271249

Get tips on using COL1A Antibody (COL-1): sc-59772 to perform Western blotting Type I collagen

Products Santa Cruz Biotechnology COL1A Antibody (COL-1): sc-59772

Get tips on using Anti-Collagen I antibody [COL-1] (ab90395) to perform Western blotting Type I collagen

Products Abcam Anti-Collagen I antibody [COL-1] (ab90395)

A key signature for necrotic cells is the permeabilization of the plasma membrane. Necrosis can be quantified by several cellular and biochemical assays. When studied minutely, it reveals the difficulty in confirmation in secondary induction of necrosis in apoptotic cells. Apoptotic cells are being analyzed to shift to necrotic status owing to membrane permeability at later stages, and thus, discrimination of two cell death becomes critical. Therefore, it is crucial to use a necrosis detection kit or a defined procedure to analyze this unprogrammed form of death in response to immense chemical and physical insults.

Cellular assays Necrosis Caco-2

A key signature for necrotic cells is the permeabilization of the plasma membrane. Necrosis can be quantified by several cellular and biochemical assays. When studied minutely, it reveals the difficulty in confirmation in secondary induction of necrosis in apoptotic cells. Apoptotic cells are being analyzed to shift to necrotic status owing to membrane permeability at later stages, and thus, discrimination of two cell death becomes critical. Therefore, it is crucial to use a necrosis detection kit or a defined procedure to analyze this unprogrammed form of death in response to immense chemical and physical insults.

Cellular assays Necrosis HCT 116
Necrosis HT-29 Experiment

A key signature for necrotic cells is the permeabilization of the plasma membrane. Necrosis can be quantified by several cellular and biochemical assays. When studied minutely, it reveals the difficulty in confirmation in secondary induction of necrosis in apoptotic cells. Apoptotic cells are being analyzed to shift to necrotic status owing to membrane permeability at later stages, and thus, discrimination of two cell death becomes critical. Therefore, it is crucial to use a necrosis detection kit or a defined procedure to analyze this unprogrammed form of death in response to immense chemical and physical insults.

Cellular assays Necrosis HT-29
Necrosis A549 Experiment

A key signature for necrotic cells is the permeabilization of the plasma membrane. Necrosis can be quantified by several cellular and biochemical assays. When studied minutely, it reveals the difficulty in confirmation in secondary induction of necrosis in apoptotic cells. Apoptotic cells are being analyzed to shift to necrotic status owing to membrane permeability at later stages, and thus, discrimination of two cell death becomes critical. Therefore, it is crucial to use a necrosis detection kit or a defined procedure to analyze this unprogrammed form of death in response to immense chemical and physical insults.

Cellular assays Necrosis A549

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms