Get tips on using Human HSP70/HSPA1A DuoSet ELISA to perform ELISA Human - HSP70
Get tips on using Human/Mouse BDNF DuoSet ELISA to perform ELISA Human - BDNF
Get tips on using Human vWF-A2 DuoSet ELISA to perform ELISA Human - VWF-A2
Get tips on using Human PDGF-BB DuoSet ELISA to perform ELISA Human - PDGF-BB
Get tips on using Human GM-CSF DuoSet ELISA to perform ELISA Human - GM-CSF
Get tips on using BMP-2 Quantikine ELISA Kit to perform ELISA Human - BMP-2
Get tips on using Gibco™ MEM α, GlutaMAX™ Supplement, no nucleosides to perform Stem cell Differentiation media Human oogonial stem cells differentiation into oocytes
Get tips on using Mouse TNFSF11/RANKL PicoKine™ ELISA Kit to perform ELISA Mouse - RANK L
ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.
ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.
Fill out your contact details and receive price quotes in your Inbox
Outsource experiment