rna-isolation-purification-tissue-mouse-spleen

- Found 7463 results

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse CD95/Fas

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse TNF-α

Get tips on using NucleoSpin® RNA/Protein to perform Protein isolation Mammalian cells - Human eutopic endometrial stromal cells

Products Macherey Nagel NucleoSpin® RNA/Protein

Get tips on using Purified Mouse Anti-Human MSH-2 Clone G219-1129 (RUO) to perform Immunohistochemistry Human - MSH2

Products BD Biosciences Purified Mouse Anti-Human MSH-2 Clone G219-1129 (RUO)

Get tips on using Monoclonal Mouse Anti-Villin (Autostainer Link 48) Clone 1D2 C3 to perform Immunohistochemistry Human - Villin

Products Agilent Technologies Monoclonal Mouse Anti-Villin (Autostainer Link 48) Clone 1D2 C3

Get tips on using Monoclonal Mouse Anti-Human Progesterone Receptor (Concentrate) Clone PgR 1294 to perform Immunohistochemistry Human - PR

Products Agilent Technologies Monoclonal Mouse Anti-Human Progesterone Receptor (Concentrate) Clone PgR 1294

Get tips on using Monoclonal Mouse Anti-Human CA 125 (Dako Omnis) Clone M11 to perform Immunohistochemistry Human - CA125

Products Agilent Technologies Monoclonal Mouse Anti-Human CA 125 (Dako Omnis) Clone M11

Get tips on using Monoclonal Mouse Anti-Human CDX2 (Dako Omnis) Clone DAK-CDX2 to perform Immunohistochemistry Human - CDX2

Products Agilent Technologies Monoclonal Mouse Anti-Human CDX2 (Dako Omnis) Clone DAK-CDX2

Get tips on using Monoclonal Anti-Proliferating Cell Nuclear Antigen antibody produced in mouse to perform Western blotting PCNA

Products Sigma-Aldrich Monoclonal Anti-Proliferating Cell Nuclear Antigen antibody produced in mouse

RNA-Seq is a method to sequence RNA by applying Next Generation Sequencing (NGS). The quality of RNA is critical for the success of RNA-Seq. The integrity of RNA is measured by the RNA integrity number (RIN). RIN is computed from RNA electrophoresis and electropherogram profiles (the peak area of the 28S rRNA should be approximately twice the peak area of the 18S rRNA). If you get the RIN value lower than 7, the possibility of getting the low quality of RNA-seq data is high. To get a high quality RNA, it is better to work with fresh samples or snap-freeze the tissues in liquid nitrogen as quickly as possible and store them at -80°C until further use. Make sure designated areas and all your filter tips, microfuge tubes, plastic, and glassware are RNase-free.

RNA RNA sequencing Human HT-1376 (urinary bladder cell line)

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms