rna-isolation-purification-cells-primary-mouse-dorsal-root-ganglion-neurons

- Found 9752 results

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse CD206

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse TCRbeta

Get tips on using Human/Mouse/Rat Phospho-Akt (S473) Pan Specific Antibody to perform Western blotting AKT

Products R&D Systems Human/Mouse/Rat Phospho-Akt (S473) Pan Specific Antibody

Get tips on using Mouse/Rat IGF-I/IGF-1 Quantikine ELISA Kit to perform ELISA Rat - IGF-I

Products R&D Systems Mouse/Rat IGF-I/IGF-1 Quantikine ELISA Kit

Get tips on using PE Mouse Anti-Human CD61 Clone VI-PL2 to perform Flow cytometry Anti-bodies Human - CD61

Products BD Biosciences PE Mouse Anti-Human CD61 Clone VI-PL2

Get tips on using PE Mouse Anti-Human CD26 Clone M-A261 to perform Flow cytometry Anti-bodies Human - CD26

Products BD Biosciences PE Mouse Anti-Human CD26 Clone M-A261

Get tips on using PE-Cy™7 Mouse Anti-Human CD10 to perform Flow cytometry Anti-bodies Human - CD10

Products BD Biosciences PE-Cy™7 Mouse Anti-Human CD10

Get tips on using PE-Cy™7 Mouse Anti-Human CD56 to perform Flow cytometry Anti-bodies Human - CD56

Products BD Biosciences PE-Cy™7 Mouse Anti-Human CD56

Get tips on using PE-Cy™7 Mouse Anti-Human CD117 to perform Flow cytometry Anti-bodies Human - CD117

Products BD Biosciences PE-Cy™7 Mouse Anti-Human CD117

Get tips on using PE-Cy™7 Mouse Anti-Human CD28 to perform Flow cytometry Anti-bodies Human - CD28

Products BD Biosciences PE-Cy™7 Mouse Anti-Human CD28

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms