siRNA / miRNA gene silencing Human Primary Endometrial Stromal Cells IGFBP1 (Insuline-like growth factor binding protein-1)

- Found 9662 results

Site-directed mutagenesis (SDM) can be challenging, particularly during detection/confirmation of (SDM) in colonies by sequencing or PCR techniques. This common issue in SDM is heavily relying on designing of mutagenic primer pairs. The best solution is to design the mutagenic primers that have extended 3'-ends/3'-overhang. This would provide the annealing region between the mutagenic primer pair is essentially shorter. and hence ensure a lower annealing temperature for the primer pair along with a higher chance of annealing to the template.

DNA Site Directed Mutagenesis (SDM) Mouse Point mutation L929 caspid protein

Proteins Protein tag Detection of proteins containing phosphorylated threonine residues

Proteins Protein tag Detection of proteins containing phosphorylated serine residues

Get tips on using CytoTox 96® Non-Radioactive Cytotoxicity Assay to perform Cell cytotoxicity / Proliferation assay cell type - BxPc-3 human primary pancreatic adenocarcinoma

Products Promega CytoTox 96® Non-Radioactive Cytotoxicity Assay

Get tips on using Absolutely RNA Nanoprep Kit to perform RNA isolation / purification Cells - primary rat dorsal root ganglion neurons

Products Agilent Technologies Absolutely RNA Nanoprep Kit

Get tips on using Aurum™ Total RNA Mini Kit to perform RNA isolation / purification Cells - primary mouse cortical neurons

Products Bio-Rad Laboratories Aurum™ Total RNA Mini Kit

Get tips on using E.Z.N.A.® Total RNA Kit I to perform RNA isolation / purification Cells - primary rat cardiac fibroblasts

Products Omega Bio Tek E.Z.N.A.® Total RNA Kit I

Get tips on using Senescence Cells Histochemical Staining Kit to perform Reporter gene assay β-galactosidase substrates - adipose stem cells

Products Sigma-Aldrich Senescence Cells Histochemical Staining Kit

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Human CD126/IL-6Ralpha

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Human CD123/IL3-R

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms