Get tips on using Oris™ Cell Migration Assay - Fibronectin Coated to perform Wound healing assay cell type - human Caco-2
Get tips on using Vybrant™ MTT Cell Proliferation Assay Kit to perform Apoptosis assay cell type - Sao2-2, MG-62
Get tips on using CellTiter 96® AQueous One Solution Cell Proliferation Assay (MTS) to perform Cell cytotoxicity / Proliferation assay cell type - LTEP-a-2 lung adenocarcenoma
Get tips on using CyQUANT® Cell Proliferation Assay Kit to perform
Get tips on using BacTiter-Glo™ Microbial Cell Viability Assay to perform Live / Dead assay yeast - Saccharomyces cerevisiae
Get tips on using BacTiter-Glo™ Microbial Cell Viability Assay to perform Live / Dead assay bacteria - Staphylococcus epidermidis
Get tips on using Viability/Cytotoxicity Assay kit for Bacteria Live and Dead Cells to perform Live / Dead assay bacteria - Salmonella enterica
Get tips on using EasySep™ Direct Human Naïve B Cell Isolation Kit to perform Cell Isolation Naive B cell
RNA-Seq is a method to sequence RNA by applying Next Generation Sequencing (NGS). The quality of RNA is critical for the success of RNA-Seq. The integrity of RNA is measured by the RNA integrity number (RIN). RIN is computed from RNA electrophoresis and electropherogram profiles (the peak area of the 28S rRNA should be approximately twice the peak area of the 18S rRNA). If you get the RIN value lower than 7, the possibility of getting the low quality of RNA-seq data is high. To get a high quality RNA, it is better to work with fresh samples or snap-freeze the tissues in liquid nitrogen as quickly as possible and store them at -80°C until further use. Make sure designated areas and all your filter tips, microfuge tubes, plastic, and glassware are RNase-free.
RNA-Seq is a method to sequence RNA by applying Next Generation Sequencing (NGS). The quality of RNA is critical for the success of RNA-Seq. The integrity of RNA is measured by the RNA integrity number (RIN). RIN is computed from RNA electrophoresis and electropherogram profiles (the peak area of the 28S rRNA should be approximately twice the peak area of the 18S rRNA). If you get the RIN value lower than 7, the possibility of getting the low quality of RNA-seq data is high. To get a high quality RNA, it is better to work with fresh samples or snap-freeze the tissues in liquid nitrogen as quickly as possible and store them at -80°C until further use. Make sure designated areas and all your filter tips, microfuge tubes, plastic, and glassware are RNase-free.
Fill out your contact details and receive price quotes in your Inbox
Outsource experiment