ChIP H3K27me3 Human Rat

- Found 4698 results

Get tips on using Galacto-Light Plus™ β-Galactosidase Reporter Gene Assay System to perform Reporter gene assay β-galactosidase substrates - RAW 264.7

Products Thermo Fisher Scientific Galacto-Light Plus™ β-Galactosidase Reporter Gene Assay System

The process of RNA extraction from bacteria, in general, involves an RNA-protective, effective lysis of bacterial cell wall (which may pose difficulties). EDTA promotes loss of outer membrane to provide lysozyme with access to peptidoglycan. Another common method for cell wall lysis is mechanical disruption using a homogenizer (applied for gram-positive bacteria and some strains of gram-negative bacteria). Following lysis, it is necessary to disrupt protein-nucleic acid interactions, which can be achieved by adding sodium dodecyl sulfate (SDS). Next step involves using phenol-chloroform-isoamyl alcohol extraction, where RNA can be obtained from the bottom organic phase, the top phase consists of DNA and the interphase contains proteins. Isoamyl alcohol is an inert and optional addition to this mixture and is added as an anti-foaming reagent to reduce the interphase. Following RNA extraction, the samples should be checked for its quality by gel electrophoresis (23S and 16S rRNAs and 5s rRNA and tRNA bands) or UV spectrophotometric or fluorescence methods.

RNA RNA isolation / purification Cells primary rabbit aortic endothelial cells

miRNA is the inherent gene silencing machinery which can have more than one mRNA target, whereas siRNA can be designed to target a particular mRNA target. By design, both siRNA and miRNA are 20-25 nucleotides in length. The target sequence for siRNAs is usually located within the open reading frame, between 50 and 100 nucleotides downstream of the start codon. There are two ways in which cells can be transfected with desired RNAi: 1. Direct transfection (with calcium phosphate co-precipitation or cationic lipid mediated transfection using lipofectamine or oligofectamine), and 2. Making RNAi lentiviral constructs (followed by transformation and transduction). Lentiviral constructs are time consuming, but provide a more permanent expression of RNAi in the cells, and consistent gene silencing. Direct transfection of oligonucleotides provides temporary genetic suppression. Traditional methods like calcium phosphate co-precipitation have challenges like low efficiency, poor reproducibility and cell toxicity. Whereas, cationic lipid-based transfection reagents are able to overcome these challenges, along with applicability to a large variety of eukaryotic cell lines. When using oligos, the ideal concentration lies between 10-50nM for effective transfection.

RNA siRNA / miRNA gene silencing Mouse RAW264.7 Sirt2

miRNA is the inherent gene silencing machinery which can have more than one mRNA target, whereas siRNA can be designed to target a particular mRNA target. By design, both siRNA and miRNA are 20-25 nucleotides in length. The target sequence for siRNAs is usually located within the open reading frame, between 50 and 100 nucleotides downstream of the start codon. There are two ways in which cells can be transfected with desired RNAi: 1. Direct transfection (with calcium phosphate co-precipitation or cationic lipid mediated transfection using lipofectamine or oligofectamine), and 2. Making RNAi lentiviral constructs (followed by transformation and transduction). Lentiviral constructs are time consuming, but provide a more permanent expression of RNAi in the cells, and consistent gene silencing. Direct transfection of oligonucleotides provides temporary genetic suppression. Traditional methods like calcium phosphate co-precipitation have challenges like low efficiency, poor reproducibility and cell toxicity. Whereas, cationic lipid-based transfection reagents are able to overcome these challenges, along with applicability to a large variety of eukaryotic cell lines. When using oligos, the ideal concentration lies between 10-50nM for effective transfection.

RNA siRNA / miRNA gene silencing Mouse RAW264.7 BNIP3

miRNA is the inherent gene silencing machinery which can have more than one mRNA target, whereas siRNA can be designed to target a particular mRNA target. By design, both siRNA and miRNA are 20-25 nucleotides in length. The target sequence for siRNAs is usually located within the open reading frame, between 50 and 100 nucleotides downstream of the start codon. There are two ways in which cells can be transfected with desired RNAi: 1. Direct transfection (with calcium phosphate co-precipitation or cationic lipid mediated transfection using lipofectamine or oligofectamine), and 2. Making RNAi lentiviral constructs (followed by transformation and transduction). Lentiviral constructs are time consuming, but provide a more permanent expression of RNAi in the cells, and consistent gene silencing. Direct transfection of oligonucleotides provides temporary genetic suppression. Traditional methods like calcium phosphate co-precipitation have challenges like low efficiency, poor reproducibility and cell toxicity. Whereas, cationic lipid-based transfection reagents are able to overcome these challenges, along with applicability to a large variety of eukaryotic cell lines. When using oligos, the ideal concentration lies between 10-50nM for effective transfection.

RNA siRNA / miRNA gene silencing Mouse RAW264.7 Rheb

DNA ladder is typically used as a reference to estimate the size of unknown DNA samples that are separated based on their mobility in an electrical field. The critical points for running a DNA ladder are compatibility with running buffer, agarose gel percentage, and choosing the correct range of DNA ladder for sizing DNA molecules.

DNA DNA Ladder Sizing

DNA ladder is typically used as a reference to estimate the size of unknown DNA samples that are separated based on their mobility in an electrical field. The critical points for running a DNA ladder are compatibility with running buffer, agarose gel percentage, and choosing the correct range of DNA ladder for sizing DNA molecules.

DNA DNA Ladder Supercoiled

DNA ladder is typically used as a reference to estimate the size of unknown DNA samples that are separated based on their mobility in an electrical field. The critical points for running a DNA ladder are compatibility with running buffer, agarose gel percentage, and choosing the correct range of DNA ladder for sizing DNA molecules.

DNA DNA Ladder Fast

DNA ladder is typically used as a reference to estimate the size of unknown DNA samples that are separated based on their mobility in an electrical field. The critical points for running a DNA ladder are compatibility with running buffer, agarose gel percentage, and choosing the correct range of DNA ladder for sizing DNA molecules.

DNA DNA Ladder 1 kb

DNA ladder is typically used as a reference to estimate the size of unknown DNA samples that are separated based on their mobility in an electrical field. The critical points for running a DNA ladder are compatibility with running buffer, agarose gel percentage, and choosing the correct range of DNA ladder for sizing DNA molecules.

DNA DNA Ladder 500 bp

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms