Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).
Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).
Get tips on using CD279 (PD-1) Monoclonal Antibody (RMP1-30), FITC, eBioscience™ to perform Flow cytometry Anti-bodies Mouse - CD279/PD-1
Get tips on using pCEP4 Mammalian Expression Vector to perform Protein expression and purification Bacteria - Origami™ B (DE3) ABCA4
Get tips on using Beta-Glo® Assay System to perform Reporter gene assay β-galactosidase substrates - rat mesenchymal stem cells (MSCs)
Get tips on using ONE-Glo™ Luciferase Assay System to perform Reporter gene assay luciferase - BHK-21 baby hamster kidney cells
Get tips on using EpiTect Bisulfite Kit to perform DNA methylation profiling Gene specific profiling - MRC-5 BARX1
Get tips on using EpiTect Bisulfite Kit to perform DNA methylation profiling Gene specific profiling - SiHa miR-375
Get tips on using EpiTect MSP Kit to perform DNA methylation profiling Gene specific profiling - Ca Ski MEG3
Get tips on using EpiScope MSP Kit to perform DNA methylation profiling Gene specific profiling - HEK 293T NELL2
Fill out your contact details and receive price quotes in your Inbox
Outsource experiment