Site-directed mutagenesis (SDM) can be challenging, particularly during detection/confirmation of (SDM) in colonies by sequencing or PCR techniques. This common issue in SDM is heavily relying on designing of mutagenic primer pairs. The best solution is to design the mutagenic primers that have extended 3'-ends/3'-overhang. This would provide the annealing region between the mutagenic primer pair is essentially shorter. and hence ensure a lower annealing temperature for the primer pair along with a higher chance of annealing to the template.
Get tips on using Stealth siRNA(m) Stac3 to perform siRNA / miRNA gene silencing Mouse - C2C12 Stac3
Get tips on using Silencer® Select_SPRY2 siRNA to perform siRNA / miRNA gene silencing Human - RMS SPRY2
Site-directed mutagenesis (SDM) can be challenging, particularly during detection/confirmation of (SDM) in colonies by sequencing or PCR techniques. This common issue in SDM is heavily relying on designing of mutagenic primer pairs. The best solution is to design the mutagenic primers that have extended 3'-ends/3'-overhang. This would provide the annealing region between the mutagenic primer pair is essentially shorter. and hence ensure a lower annealing temperature for the primer pair along with a higher chance of annealing to the template.
Get tips on using SignalSilence® SAPK/JNK siRNA to perform siRNA / miRNA gene silencing Human - KGN SAPK/JNK
RNA-Seq is a method to sequence RNA by applying Next Generation Sequencing (NGS). The quality of RNA is critical for the success of RNA-Seq. The integrity of RNA is measured by the RNA integrity number (RIN). RIN is computed from RNA electrophoresis and electropherogram profiles (the peak area of the 28S rRNA should be approximately twice the peak area of the 18S rRNA). If you get the RIN value lower than 7, the possibility of getting the low quality of RNA-seq data is high. To get a high quality RNA, it is better to work with fresh samples or snap-freeze the tissues in liquid nitrogen as quickly as possible and store them at -80°C until further use. Make sure designated areas and all your filter tips, microfuge tubes, plastic, and glassware are RNase-free.
Get tips on using ON-TARGETplus Mouse Stat5b (20851) siRNA - SMARTpool to perform siRNA / miRNA gene silencing Mouse - FL83B Stat5b
Get tips on using ON-TARGETplus Mouse Sirt2 (64383) siRNA - SMARTpool to perform siRNA / miRNA gene silencing Mouse - RAW264.7 Sirt2
Get tips on using ON-TARGETplus Human SLX1A (548593) siRNA - SMARTpool to perform siRNA / miRNA gene silencing Human - U2OS SLX1A
Get tips on using ON-TARGETplus Human SLX4 (84464) siRNA - SMARTpool to perform siRNA / miRNA gene silencing Human - U2OS SLX4
Fill out your contact details and receive price quotes in your Inbox
Outsource experiment