Immunohistochemistry Collagen VII antibody [LH7.2] Mouse Human

- Found 6217 results

Get tips on using CD86 (B7-2) Monoclonal Antibody (GL1), APC, eBioscience™ to perform Flow cytometry Anti-bodies Mouse - CD86

Products eBioscience CD86 (B7-2) Monoclonal Antibody (GL1), APC, eBioscience™

Get tips on using CD8a Monoclonal Antibody (53-6.7), eFluor 450, eBioscience™ to perform Flow cytometry Anti-bodies Mouse - CD8a

Products eBioscience CD8a Monoclonal Antibody (53-6.7), eFluor 450, eBioscience™

Get tips on using CD11b Monoclonal Antibody (M1/70), eFluor 450, eBioscience™ to perform Flow cytometry Anti-bodies Mouse - CD11b

Products eBioscience CD11b Monoclonal Antibody (M1/70), eFluor 450, eBioscience™

Get tips on using CD45 Monoclonal Antibody (30-F11), PE-Cyanine7, eBioscience™ to perform Flow cytometry Anti-bodies Mouse - CD45

Products eBioscience CD45 Monoclonal Antibody (30-F11), PE-Cyanine7, eBioscience™

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse Ly-6A-E/Sca1

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse Ly6C/Gr-1/Ly6G

Get tips on using Anti-LC3B antibody produced in rabbit to perform Autophagy assay cell type - Human tracheobronchial epithelial cells (hTEC)

Products Sigma-Aldrich Anti-LC3B antibody produced in rabbit

Get tips on using FlowCellect Autophagy LC3 antibody based kit to perform Autophagy assay cell type - MT-2 (human T cell leukaemia)

Products Millipore FlowCellect Autophagy LC3 antibody based kit

ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.

Proteins ELISA Mouse Angiopoietin-Like 3 (AngptL3)

ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.

Proteins ELISA Mouse C-Reactive Protein/CRP

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms