dna-methylation-profiling-gene-specific-profiling-caco-1-chst11

- Found 5749 results

Get tips on using Anti-Beclin 1 antibody [2A4] (ab114071) to perform Autophagy assay cell type - Hepatocytes

Products Abcam Anti-Beclin 1 antibody [2A4] (ab114071)

Get tips on using Anti-Beclin 1 antibody [2A4] (ab114071) to perform Autophagy assay cell type - Hepatocytes

Products Abcam Anti-Beclin 1 antibody [2A4] (ab114071)

Get tips on using Anti-Beclin 1 antibody [2A4] (ab114071) to perform Autophagy assay cell type - Saos

Products Abcam Anti-Beclin 1 antibody [2A4] (ab114071)

ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.

Proteins ELISA Human Chitinase-3-Like Protein-1 (CHI3L1) or YKL-40

ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.

Proteins ELISA Mouse Chitinase-3-Like Protein-1 (CHI3L1) or YKL-40

RNA-Seq is a method to sequence RNA by applying Next Generation Sequencing (NGS). The quality of RNA is critical for the success of RNA-Seq. The integrity of RNA is measured by the RNA integrity number (RIN). RIN is computed from RNA electrophoresis and electropherogram profiles (the peak area of the 28S rRNA should be approximately twice the peak area of the 18S rRNA). If you get the RIN value lower than 7, the possibility of getting the low quality of RNA-seq data is high. To get a high quality RNA, it is better to work with fresh samples or snap-freeze the tissues in liquid nitrogen as quickly as possible and store them at -80°C until further use. Make sure designated areas and all your filter tips, microfuge tubes, plastic, and glassware are RNase-free.

RNA RNA sequencing Rat INS-1 832/13

Get tips on using AMPIPROBE® Candida 1 Assay Kit to perform Cell Culture Contamination Detection Kit Yeast

Products Enzo Life Sciences AMPIPROBE® Candida 1 Assay Kit

Get tips on using Hop Antibody (E-1): sc-398703 to perform Flow cytometry Anti-bodies Mouse - HOPX

Products Santa Cruz Biotechnology Hop Antibody (E-1): sc-398703

Get tips on using Ki-67 Antigen, Clone MIB-1 to perform Immunohistochemistry Ki67 - Rabbit Mouse / Human -NA-

Products DAKO Ki-67 Antigen, Clone MIB-1

Get tips on using Wilms' Tumor 1 (WT1) Protein, Clone 6F-H2 to perform Immunohistochemistry Wilms Tumor 1 (WT1) - Rabbit Mouse -NA-

Products Dianova Wilms' Tumor 1 (WT1) Protein, Clone 6F-H2

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms