Immunohistochemistry Anti-mouse IgG

- Found 3774 results

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Human CD140/PDFGR2

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Human HLA-DR

Get tips on using Atg12 Antibody (Mouse Specific) #2011 to perform Autophagy assay cell type - MEFs (mouse embryonic fibroblasts)

Products Cell Signaling Technology Atg12 Antibody (Mouse Specific) #2011

Get tips on using Anti-PI 3 Kinase p85 alpha (phospho Y607) antibody to perform Autophagy assay cell type - HepG2

Products Abcam Anti-PI 3 Kinase p85 alpha (phospho Y607) antibody

Get tips on using Anti-PI3-kinase p85-α antibody produced in rabbit to perform Autophagy assay cell type - HepG2

Products Sigma-Aldrich Anti-PI3-kinase p85-α antibody produced in rabbit

Get tips on using Anti-Histone H3 (tri methyl K36) antibody - ChIP Grade to perform ChIP H3K36Me3 - Sheep Rat -NA-

Products Abcam Anti-Histone H3 (tri methyl K36) antibody - ChIP Grade

Get tips on using Mouse IGF-1 PicoKine™ ELISA Kit to perform ELISA Mouse - IGF-I

Products BosterBio Mouse IGF-1 PicoKine™ ELISA Kit

Get tips on using Anti-Histone H3 (tri methyl K36) antibody - ChIP Grade to perform ChIP H3K27me3 - Sheep Rat YFP Tag

Products Abcam Anti-Histone H3 (tri methyl K36) antibody - ChIP Grade

ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.

Proteins ELISA Mouse Adiponectin

ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.

Proteins ELISA Mouse BDNF

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms