No discussions found
Start your discussion
Share your thoughts or question with experts in your field
Start a discussion
Found 2 matching solutions for this experiment
Upstream tips |
Protocol tips |
Downstream tips |
-Bring all reagents to room temperature (18-25°C) before use for 30min.
-Prepare fresh standard for each assay. Use within 4 hours and discard after use.
-Centrifuge the sample again after thawing before the assay. |
- To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary. Do not allow wells to sit uncovered for extended periods between incubation steps.
-Once reagents have been
added to the well strips, DO NOT let the strips DRY at any time during the assay.
-TMB Substrate should remain colorless or light blue until added to the plate. Please protect it from light.
-Stop Solution should be added to the plate in the same order as the TMB Substrate. |
|
Upstream tips |
-Bring all reagents to room temperature (18-25°C) before use for 30min.
-Prepare fresh standard for each assay. Use within 4 hours and discard after use.
-Centrifuge the sample again after thawing before the assay. |
Protocol tips |
- To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary. Do not allow wells to sit uncovered for extended periods between incubation steps.
-Once reagents have been
added to the well strips, DO NOT let the strips DRY at any time during the assay.
-TMB Substrate should remain colorless or light blue until added to the plate. Please protect it from light.
-Stop Solution should be added to the plate in the same order as the TMB Substrate. |
Upstream tips |
Protocol tips |
Downstream tips |
-Equilibrate all reagents to room temperature (18-25°C) prior to use. |
-Avoid foaming or bubbles when mixing or reconstituting components.
-Ensure plates are properly sealed or covered during incubation steps.
-Complete removal of all solutions and buffers during wash steps is necessary to minimize background. |
-Unused well strips should be returned to the plate packet and
stored at 4°C. |
Upstream tips |
-Equilibrate all reagents to room temperature (18-25°C) prior to use. |
Protocol tips |
-Avoid foaming or bubbles when mixing or reconstituting components.
-Ensure plates are properly sealed or covered during incubation steps.
-Complete removal of all solutions and buffers during wash steps is necessary to minimize background. |
Downstream tips |
-Unused well strips should be returned to the plate packet and
stored at 4°C. |
Can't find the product you've used to perform this experiment? It would be great if you can help us by
Adding a product!