ELISA Mouse - RBP4

ELISA is the most commonly used method of detecting and quantifying the concentration of an antigen in an unknown sample. During the experiment, If you get a weak signal, then make sure reagents are at room temperature before starting the assay. Try increasing incubation times to ensure maximal antibody binding and amplify the signal. Secondly, if you get values above 0 in the negative control indicates a high background signal. Try to consider reducing your antibody concentration and prevent non-specific binding of antibodies by using affinity-purified antibody and suitable blocking buffers. To avoid high well to well variation, do not stack plates during incubation, no bubbles in the plate and wash wells thoroughly to avoid variation.

Start discussion

No discussions found

Start your discussion

Share your thoughts or question with experts in your field

Start a discussion

Found 3 matching solutions for this experiment

Upstream tips
-Store the unopened kit at 2-8 °C.
-Bring all reagents to room temperature before use.
-Reconstitute the Human Cytochrome c Standard with deionized or distilled water. Allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making dilutions.
Protocol tips
-When mixing or reconstituting protein solutions, always avoid foaming.
-Substrate Solution should remain colorless until added to the plate.
-Keep Substrate solution protected from light.
-Stop Solution should be added to the plate in the same order as the Substrate Solution.
-Wells that are green in color indicate that the Stop Solution has not mixed thoroughly with
the Substrate Solution.
Upstream tips
-Inspect all reagents prior to use. Components should contain no particulates or cloudiness and should be
colorless.
-Prior to using the kit, briefly spin component tubes to collect all reagent at the bottom.
-Equilibrate all materials to room temperature prior to use and use prepare immediately prior to use.
Protocol tips
-Cover microplate while incubating to prevent evaporation.
-Do not allow the microplate wells dry at any point during the assay procedure.
-Avoid causing bubbles or foaming when pipetting, mixing or reconstituting.
Downstream tips
-Unused well strips should be returned to the original packaging, sealed and stored at 4°C.
Upstream tips
-Equilibrate all reagents to room temperature (18-25°C) prior to use.
Protocol tips
-Avoid foaming or bubbles when mixing or reconstituting components.
-Ensure plates are properly sealed or covered during incubation steps.
-Complete removal of all solutions and buffers during wash steps is necessary to minimize background.
Downstream tips
-Unused well strips should be returned to the plate packet and
stored at 4°C.
Can't find the product you've used to perform this experiment? It would be great if you can help us by Adding a product!

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms