No discussions found
Start your discussion
Share your thoughts or question with experts in your field
Start a discussion
Found 3 matching solutions for this experiment
Upstream tips |
Protocol tips |
Downstream tips |
|
Heparinized bone marrow (BM) and peripheral blood (PB) cells (106 leukocytes per tube) were incubated with various combinations of mAb (Supplementary Table S3) for 15 minutes. Then, erythrocytes were lysed in FACS-Lysing-Solution (BD Biosciences, San José, CA, USA). Washed cells were acquired on a FACSCalibur (BD Biosciences) and analyzed by FlowJo software (TreeStar, Ashland, OR, USA) as reported |
|
Protocol tips |
Heparinized bone marrow (BM) and peripheral blood (PB) cells (106 leukocytes per tube) were incubated with various combinations of mAb (Supplementary Table S3) for 15 minutes. Then, erythrocytes were lysed in FACS-Lysing-Solution (BD Biosciences, San José, CA, USA). Washed cells were acquired on a FACSCalibur (BD Biosciences) and analyzed by FlowJo software (TreeStar, Ashland, OR, USA) as reported |
Upstream tips |
Protocol tips |
Downstream tips |
|
BM-MSCs and UC-MSCs were harvested by trypsinisation at P0 and P1, pelleted and 20,000 cells per tube were re-suspended in 2% BSA for flow cytometry as described previously. The following antibodies against markers indicative of MSC profiles |
Cells were analysed on a FACSCanto II flow cytometer using Diva 7 software (Becton Dickinson & company, Oxford, UK) |
Protocol tips |
BM-MSCs and UC-MSCs were harvested by trypsinisation at P0 and P1, pelleted and 20,000 cells per tube were re-suspended in 2% BSA for flow cytometry as described previously. The following antibodies against markers indicative of MSC profiles |
Downstream tips |
Cells were analysed on a FACSCanto II flow cytometer using Diva 7 software (Becton Dickinson & company, Oxford, UK) |
Upstream tips |
Protocol tips |
Downstream tips |
|
Measurements of EPCs and MPs were performed as previously reported, using fresh blood samples in EDTA containing tubes. |
For determination of EPCs, a minimum of 500,000 events was acquired by flow-cytometry (FACSCalibur, BD Biosciences, USA) |
Protocol tips |
Measurements of EPCs and MPs were performed as previously reported, using fresh blood samples in EDTA containing tubes. |
Downstream tips |
For determination of EPCs, a minimum of 500,000 events was acquired by flow-cytometry (FACSCalibur, BD Biosciences, USA) |
Can't find the product you've used to perform this experiment? It would be great if you can help us by
Adding a product!