Found 4 matching solutions for this experiment
Upstream tips |
Protocol tips |
Downstream tips |
• Apoptosis/ Necrosis Detection Kit (blue, green, red) (ab176749) is designed to simultaneously monitor apoptotic, necrotic and healthy cells.
• The PS sensor used in this kit has green fluorescence (Ex/Em = 490/525 nm) upon binding to membrane PS. |
• 5 X 10^5 cells were seeded in 6-well plates for 24 h |
|
Upstream tips |
• Apoptosis/ Necrosis Detection Kit (blue, green, red) (ab176749) is designed to simultaneously monitor apoptotic, necrotic and healthy cells.
• The PS sensor used in this kit has green fluorescence (Ex/Em = 490/525 nm) upon binding to membrane PS. |
Protocol tips |
• 5 X 10^5 cells were seeded in 6-well plates for 24 h |
Upstream tips |
Protocol tips |
Downstream tips |
• Detection Method Flow cytometry (Ex = 488 nm; Em = 530 nm) and fluorescence microscopy
• Species Reactivity: Mammalian
• Applications: Detect early/middle stages of apoptosis; differentiate apoptosis from necrosis. |
• Seed 100,000 cells/mL in 6-well plates. |
|
Upstream tips |
• Detection Method Flow cytometry (Ex = 488 nm; Em = 530 nm) and fluorescence microscopy
• Species Reactivity: Mammalian
• Applications: Detect early/middle stages of apoptosis; differentiate apoptosis from necrosis. |
Protocol tips |
• Seed 100,000 cells/mL in 6-well plates. |
Upstream tips |
Protocol tips |
Downstream tips |
• Kit provides a convenient assay for quantifying apoptotic (green) and necrotic (red) cells within the same cell population by flow cytometry or fluorescence microscopy. |
• Seed 1 × 10^3 MiaCaPa-2 cells in each well. |
|
Upstream tips |
• Kit provides a convenient assay for quantifying apoptotic (green) and necrotic (red) cells within the same cell population by flow cytometry or fluorescence microscopy. |
Protocol tips |
• Seed 1 × 10^3 MiaCaPa-2 cells in each well. |
Hoechst 33342 + Propidium Iodide - 1.0 mg/mL Solution in Water
Upstream tips |
Protocol tips |
Downstream tips |
• Differential Staining for apoptosis and necrosis |
• Seed 15,000 cells/well |
•Apoptotic and necrotic cells were counted and the percentage number of cells was calculated. |
Upstream tips |
• Differential Staining for apoptosis and necrosis |
Protocol tips |
• Seed 15,000 cells/well |
Downstream tips |
•Apoptotic and necrotic cells were counted and the percentage number of cells was calculated. |