RNA isolation / purification Cells - immortalized RPMI 2650

When extracting nucleic acids from cell cultures, thorough homogenization of cells via vortexing in lysis buffer is very necessary. Choose the best RNA isolation method keeping in mind the downstream applications, generally, column-based isolations result in clean and concentrated RNA samples. Downstream applications like sequencing and cDNA synthesis require high-quality RNA, always treat the samples with DNases and check their integrity by running a gel.

Start discussion

Found 1 discussion for this experiment

Discussion

5 years ago

5 years ago by Ralf Friedmann Switzerland

I am having trouble using the QiageN RNAeasy mini kit for CD34+ cells. Any tips?

I am having trouble using the QiageN RNAeasy mini kit for CD34+ cells. Any tips?

Share your thoughts or question with experts in your field by adding a discussion!

Found 2 matching solutions for this experiment

Protocol tips
- To yield high RNA, give the column an extra wash with both RW1 and RPE buffers (3 total washes with each buffer).
Downstream tips
- Include DNAse treatment for 15-20min.

- Ensure EtOH is completely evaporated off of the column prior to elution. Adjust time from 1min to 5 min at 60`C.

- Use water to elute the RNA that is warmed to ~60`C.

- For purifying RNA add either 10 μl β-mercapto ethanol (β-ME) or 20 μl 2 M dithiothreitol (DTT).
TRIzol Reagent

Thermo Fisher Scientific

Protocol tips
- For low 260/230 readings the best approach is to try washing sample (precipitation) with ethanol to desalt it.
Can't find the product you've used to perform this experiment? It would be great if you can help us by Adding a product!

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms