RNA isolation / purification Cells - primary human mesenchymal stem cells

When extracting nucleic acids from cell cultures, thorough homogenization of cells via vortexing in lysis buffer is very necessary. Choose the best RNA isolation method keeping in mind the downstream applications, generally, column-based isolations result in clean and concentrated RNA samples. Downstream applications like sequencing and cDNA synthesis require high-quality RNA, always treat the samples with DNases and check their integrity by running a gel.

Start discussion

Found 1 discussion for this experiment

Discussion

5 years ago

5 years ago by Ralf Friedmann Switzerland

I am having trouble using the QiageN RNAeasy mini kit for CD34+ cells. Any tips?

I am having trouble using the QiageN RNAeasy mini kit for CD34+ cells. Any tips?

Share your thoughts or question with experts in your field by adding a discussion!

Found 3 matching solutions for this experiment

NucleoSpin® miRNA

Macherey Nagel

Protocol tips
Total RNA was extracted using NucleoSpin miRNA kit (Macherey-Nagel, Düren, Germany) and converted to cDNA using cDNA Reverse Transcription Kit (Applied Biosystems, Darmstadt, Germany). Quality of RNA was analyzed with the Agilent Bioanalyzer (Agilent Technologies, Santa Clara, USA).
Upstream tips
- This kit can be used for the isolation of RNA from up to 1x10^6 cells
Can't find the product you've used to perform this experiment? It would be great if you can help us by Adding a product!