Guava Cell Cycle Reagent for Flow Cytometry

Cell cycle assay human - U20S

Experiment
Cell cycle assay human - U20S
Product
Guava Cell Cycle Reagent for Flow Cytometry from Merck Millipore
Manufacturer
Merck Millipore

Protocol tips

Protocol tips
- The fixed cells were centrifuged at 800 Xg for 5 min at 4 °C

- Suspended cells were treated with RNase A at 37 °C for 1 h followed by staining with Reagent.

Publication protocol

Control and transfected cells were harvested by trypsin (0.25%). Cell pellets were washed with cold PBS and then added drop-wise to pre-chilled 70% ethanol. The fixed cells were centrifuged at 800 Xg for 5 min at 4 °C, washed with cold PBS twice and then re-suspended in 0.25 ml PBS. The cells suspensions were treated with RNase A at 37 °C for 1 h followed by brief centrifugation to discard supernatant. Cells were re-suspended in 200 μl of Cell Cycle Guava reagent (Millipore, Billerica, MA, USA), incubated for 30 min in dark, and analyzed by EasyCyte Guava cytometer (Millipore). The data were further analyzed using FlowJo software.

Full paper   Login or join for free to view the full paper.

Reviews

Guava Cell Cycle Reagent for Flow Cytometry from Merck Millipore has not yet been reviewed for this experiment

We'd love it if you would be the first to write a review!

Discussion

Start your discussion

Share your thoughts or question with experts in your field

Start a discussion

Papers

Check out relevant papers found by Labettor's AI that are relevant for performing Cell cycle assay human - U20S using Guava Cell Cycle Reagent for Flow Cytometry from Merck Millipore.

Paper title
Loss-of-function screening to identify miRNAs involved in senescence: tumor suppressor activity of miRNA-335 and its new target CARF
Full paper
Login or join for free to view the full paper.

Manufacturer protocol

Download the product protocol from Merck Millipore for Guava Cell Cycle Reagent for Flow Cytometry below.

Download PDF Download manufacturer protocol

Videos

Check out videos that might be relevant for performing Cell cycle assay human - U20S using Guava Cell Cycle Reagent for Flow Cytometry from Merck Millipore. Please note that these videos are representative and steps or experiment specific processes must be kept in mind to expect desired results.

We haven't found any additional videos for this experiment / product combination yet.

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms