SurePrint G3 Human CGH Microarray Kit, 4x180K

Microarray Comperative genomic hybridization - Human MDA-MB-361

Experiment
Microarray Comperative genomic hybridization - Human MDA-MB-361
Product
SurePrint G3 Human CGH Microarray Kit, 4x180K from Agilent Technologies
Manufacturer
Agilent Technologies

Protocol tips

Upstream tips
Avoid touching the surface of
the glass with your fingers. Skin oils and other substances, such as
lotions or ink, can fluoresce. If the surface of the glass is noticeably dirty, it can be carefully cleaned with a nonabrasive laboratory tissue.

Publication protocol

Array comparative genomic hybridization
Array CGH was performed on oligonucleotide-based SurePrint G3 Human CGH 4×180K microarray slides (design code: 022060) according the protocol provided by the manufacturer (Agilent Oligonucleotide Array-Based CGH for Genomic DNA Analysis, version 7.1, December 2011). Slight modifications were introduced WGA products processed with the PCR-based labeling approaches. Here, the hybridization mix consisted of 5.0 µg of Cot1-DNA (Roche Diagnostics), 12 µl of 10x Blocking Reagent (Agilent Technologies), 60 µl of 2x Hi RPM Hybridization Buffer, 1% (v/v) of both Tween20 and Igepal and 19 µl of both test and reference DNA. For each hybridization 100 µl of the hybridization mix was applied on the array and hybridized at 65°C for 24 h. Following the hybridization, the slides were washed twice for 2:30 min in Oligo aCGH/ChIP-on-Chip Wash Buffer 1 (Agilent Technologies) at room temperature, twice for 30 sec min in Oligo aCGH/ChIP-on-Chip Wash Buffer 2 (Agilent Technologies) at 37°C. Washed slides were immersed in acetonitrile to remove all remaining traces of the wash buffers. Finally, slides were scanned using an Agilent Microarray Scanner Type C.

Full paper   Login or join for free to view the full paper.

Reviews

SurePrint G3 Human CGH Microarray Kit, 4x180K from Agilent Technologies has not yet been reviewed for this experiment

We'd love it if you would be the first to write a review!

Discussion

Start your discussion

Share your thoughts or question with experts in your field

Start a discussion

Papers

Check out relevant papers found by Labettor's AI that are relevant for performing Microarray Comperative genomic hybridization - Human MDA-MB-361 using SurePrint G3 Human CGH Microarray Kit, 4x180K from Agilent Technologies.

Paper title
Reliable Single Cell Array CGH for Clinical Samples
Full paper
Login or join for free to view the full paper.

Manufacturer protocol

Download the product protocol from Agilent Technologies for SurePrint G3 Human CGH Microarray Kit, 4x180K below.

Download PDF Download manufacturer protocol

Videos

Check out videos that might be relevant for performing Microarray Comperative genomic hybridization - Human MDA-MB-361 using SurePrint G3 Human CGH Microarray Kit, 4x180K from Agilent Technologies. Please note that these videos are representative and steps or experiment specific processes must be kept in mind to expect desired results.

We haven't found any additional videos for this experiment / product combination yet.

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms