Protocol tips
Upstream tips |
Protocol tips |
Downstream tips |
|
Seed the cells in 8 well chamber slide to 30% confluency. After the appropriate treatment incubate with 100μl of dual detection reagent. |
Incase of Low CYTO-ID Green dye staining in all treatments, increase the reagent concentration (500X dilution of the dye is recommended) and the incubation time.
Incase of High CYTO-ID Green staining, it could be that the cell culture medium was depleted of nutrients and so change media 4-8 hours before the experiment. |
Protocol tips |
Seed the cells in 8 well chamber slide to 30% confluency. After the appropriate treatment incubate with 100μl of dual detection reagent. |
Downstream tips |
Incase of Low CYTO-ID Green dye staining in all treatments, increase the reagent concentration (500X dilution of the dye is recommended) and the incubation time.
Incase of High CYTO-ID Green staining, it could be that the cell culture medium was depleted of nutrients and so change media 4-8 hours before the experiment. |
Publication protocol
Autophagy was detected in MCL cells infected or not with LC3-GFP retroviral expression vector. 106 cells were labeled using the Cyto-ID® Autophagy Detection Kit (Enzo Life Sciences) according to manufacturer's instructions. Cells undergoing autophagy showed green fluorescent countable punctuate structures. Similarly, in cells infected with LC3-GFP retroviral expression vector, the autophagy extent is measurable through the counting of LC3-GFP puncta per cell. 50×103 cells/sample were acquired with the ImageStreamX instrument (Amnis Corporation, Seattle, WA) using the INSPIRE software and, using a specific feature of the IDEAS analysis software, the number of fluorescent spots per cell was evaluated. The “H variance mean” algorithm of the IDEAS software allowed to evaluate the distribution and the texture of fluorescence into the cells also in the presence of high background
Full paper
Login or
join for free to view the full paper.
Reviews
CYTO-ID® Autophagy detection kit from Enzo Life Sciences has not yet been reviewed for this experiment
We'd love it if you would be the first to write a review!
Discussion
Start your discussion
Share your thoughts or question with experts in your field
Start a discussion
Papers
Check out relevant papers found by Labettor's AI that are relevant for performing Autophagy assay cell type - Mino using CYTO-ID® Autophagy detection kit from Enzo Life Sciences.
Paper title
Phospholipid scramblase 1 as a critical node at the crossroad between autophagy and apoptosis in mantle cell lymphoma
Manufacturer protocol
Download the product protocol from Enzo Life Sciences for CYTO-ID® Autophagy detection kit below.
Download manufacturer protocol
Videos
Check out videos that might be relevant for performing Autophagy assay cell type - Mino using CYTO-ID® Autophagy detection kit from Enzo Life Sciences. Please note that these videos are representative and steps or experiment specific processes must be kept in mind to expect desired results.
We haven't found any additional videos for this experiment / product combination yet.