Protocol tips
Upstream tips |
Protocol tips |
Downstream tips |
This kit uses a green fluorescent probe that reacts with autophagic vacuoles and is detectable by flow cytometry |
Incubate cells with CYTO-ID dye (2μl of CYTO-ID in 1ml of 1X assay buffer) for 30 min |
Incase of Low CYTO-ID Green dye staining in all treatments, increase the reagent concentration (500X dilution of the dye is recommended) and the incubation time.
Incase of High CYTO-ID Green staining, it could be that the cell culture medium was depleted of nutrients and so change media 4-8 hours before the experiment.
|
Upstream tips |
This kit uses a green fluorescent probe that reacts with autophagic vacuoles and is detectable by flow cytometry |
Protocol tips |
Incubate cells with CYTO-ID dye (2μl of CYTO-ID in 1ml of 1X assay buffer) for 30 min |
Downstream tips |
Incase of Low CYTO-ID Green dye staining in all treatments, increase the reagent concentration (500X dilution of the dye is recommended) and the incubation time.
Incase of High CYTO-ID Green staining, it could be that the cell culture medium was depleted of nutrients and so change media 4-8 hours before the experiment.
|
Publication protocol
HL‐1 cells transfected with Ehmt2 siRNA or negative control siRNA (as described above) were either treated with 5 μmol/L rapamycin for 18 hours or cultured in serum‐free medium (Hank's Balanced Salt Solution, Thermo Fisher) containing 10 μmol/L chloroquine for 4 hours to induce autophagy. Two separate experiments with at least 6 biological replicates in each treatment group were performed. Autophagic activity was probed using the CYTO‐ID Autophagy Detection Kit (Enzo Life Sciences, Farmingdale, NY) and measured with flow cytometry. For quantification of autophagy, cells were stained as per the manufacturer's instructions and run in a BD Accuri Flow Cytometer. The mean fluorescence intensity in FL‐1 was used as a measure of autophagic activity.
Full paper
Login or
join for free to view the full paper.
Reviews
CYTO-ID® Autophagy detection kit from Enzo Life Sciences has not yet been reviewed for this experiment
We'd love it if you would be the first to write a review!
Discussion
Start your discussion
Share your thoughts or question with experts in your field
Start a discussion
Papers
Check out relevant papers found by Labettor's AI that are relevant for performing Autophagy assay cell type - HL-1 using CYTO-ID® Autophagy detection kit from Enzo Life Sciences.
Paper title
Ischemic Preconditioning Confers Epigenetic Repression of and Induction of Autophagy Through G9a‐Dependent H3K9 Dimethylation
Manufacturer protocol
Download the product protocol from Enzo Life Sciences for CYTO-ID® Autophagy detection kit below.
Download manufacturer protocol
Videos
Check out videos that might be relevant for performing Autophagy assay cell type - HL-1 using CYTO-ID® Autophagy detection kit from Enzo Life Sciences. Please note that these videos are representative and steps or experiment specific processes must be kept in mind to expect desired results.
We haven't found any additional videos for this experiment / product combination yet.