Protocol tips
Upstream tips |
Protocol tips |
Downstream tips |
This kit uses a green fluorescent probe that reacts with autophagic vacuoles and is detectable by flow cytometry |
Use Cyto-ID green dye (1 μl/4 ml assay buffer) for 30 minutes in dark at RT. |
Incase of Low CYTO-ID Green dye staining in all treatments, increase the reagent concentration (500X dilution of the dye is recommended) and the incubation time.
Incase of High CYTO-ID Green staining, it could be that the cell culture medium was depleted of nutrients and so change media 4-8 hours before the experiment.
|
Upstream tips |
This kit uses a green fluorescent probe that reacts with autophagic vacuoles and is detectable by flow cytometry |
Protocol tips |
Use Cyto-ID green dye (1 μl/4 ml assay buffer) for 30 minutes in dark at RT. |
Downstream tips |
Incase of Low CYTO-ID Green dye staining in all treatments, increase the reagent concentration (500X dilution of the dye is recommended) and the incubation time.
Incase of High CYTO-ID Green staining, it could be that the cell culture medium was depleted of nutrients and so change media 4-8 hours before the experiment.
|
Publication protocol
The flow cytometric investigation of Cyto-ID Green Detection Reagent stained cells was performed according to the manufacturer's protocol (Cyto-ID Autophagy Detection Kit, Enzo Life Sciences). Cells were analyzed using FACSCanto II (Becton Dickinson) as discussed previously [11]. Relative autophagy level was normalized to untreated control cells.
Full paper
Login or
join for free to view the full paper.
Reviews
CYTO-ID® Autophagy detection kit from Enzo Life Sciences has not yet been reviewed for this experiment
We'd love it if you would be the first to write a review!
Discussion
Start your discussion
Share your thoughts or question with experts in your field
Start a discussion
Papers
Check out relevant papers found by Labettor's AI that are relevant for performing Autophagy assay cell type - U87MG using CYTO-ID® Autophagy detection kit from Enzo Life Sciences.
Paper title
Artesunate enhances the therapeutic response of glioma cells to temozolomide by inhibition of homologous recombination and senescence
Manufacturer protocol
Download the product protocol from Enzo Life Sciences for CYTO-ID® Autophagy detection kit below.
Download manufacturer protocol
Videos
Check out videos that might be relevant for performing Autophagy assay cell type - U87MG using CYTO-ID® Autophagy detection kit from Enzo Life Sciences. Please note that these videos are representative and steps or experiment specific processes must be kept in mind to expect desired results.
We haven't found any additional videos for this experiment / product combination yet.