Protocol tips

Upstream tips
-Bring all reagents to room temperature before use. Allow all components to sit for a minimum of 15 minutes with gentle agitation after initial reconstitution.
-Working dilutions should be prepared and used immediately.
Protocol tips
-A standard curve should be generated for each set of samples assayed.
-It is suggested to start Reagent Diluent optimization for serum and plasma samples by using PBS supplemented with 10-50% animal serum.
-Do not use buffers with animal serum to reconstitute or dilute the Detection Antibody or Streptavidin-HRP B.

Publication protocol

Neutrophil gelatinase-associated lipocalin (NGAL), tissue inhibitor metalloproteinase type 2 and insulin-like growth factor-binding protein type 7 (TIMP-2*IGFBP-7), kidney injury molecule 1 (KIM-1), interleukin-18 (IL-18), and liver-type fatty acid-binding protein (L-FABP) were measured on the urine samples collected at baseline (prior to CPB initiation) and then at 2, 6, 12, 24, 48, and 72 hours following CPB initiation. TIMP-2*IGFBP-7 was measured using the Astute® 140 meter (Astute Medical, Inc., San Diego, California). The authors have previously reported the cut-off points of TIMP-2*IGFBP-7 associated with AKI [20]. Urine NGAL was measured using a commercially available assay (NGAL ELISA Kit 036; Bioporto, Grusbakken, Denmark) that specifically detects human NGAL [26]. The intra-assay CV was 2.1% and inter-assay variation was 9.1%. Urine IL-18 (Kit 7625) and L-FABP (Kit Z-001) were measured using commercially available ELISA kits (Medical & Biological Laboratories Co., Nagoya, Japan and CMIC Co., Tokyo, Japan, respectively) per manufacturer’s instructions. Intra-assay CV for IL-18 and L-FABP were 7.3% and 6.1% respectively. Interassay CV were 7.5% and 10.9% for IL-18 and L-FABP respectively. The urine KIM-1 ELISA was performed using validated commercially available reagents (Duoset DY1750, R & D Systems, Inc., Minneapolis, MN) as previously described.

Full paper   Login or join for free to view the full paper.

Reviews

Human TIM-1/KIM-1/HAVCR DuoSet ELISA from R&D Systems has not yet been reviewed for this experiment

We'd love it if you would be the first to write a review!

Discussion

Start your discussion

Share your thoughts or question with experts in your field

Start a discussion

Papers

Check out relevant papers found by Labettor's AI that are relevant for performing ELISA Human - KIM-1 using Human TIM-1/KIM-1/HAVCR DuoSet ELISA from R&D Systems.

View full paper   Login or join for free to view the full paper.

Manufacturer protocol

Download the product protocol from R&D Systems for Human TIM-1/KIM-1/HAVCR DuoSet ELISA below.

Download PDF Download manufacturer protocol

Videos

Check out videos that might be relevant for performing ELISA Human - KIM-1 using Human TIM-1/KIM-1/HAVCR DuoSet ELISA from R&D Systems. Please note that these videos are representative and steps or experiment specific processes must be kept in mind to expect desired results.

We haven't found any additional videos for this experiment / product combination yet.

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms