Protocol tips
Upstream tips |
Protocol tips |
Downstream tips |
Each cell type was single cell suspended and, incubated in FACS buffer containing pre-conjugated antibodies (see supplementary Table 2) for 20 min on ice. |
. Following incubation, cells were washed twice with FACS buffer. |
All the flow cytometry performed using a Cell Lab Quanta SCMPL. The data were analyzed using Kaluza®1.2 software (Beckman Coulter, Denmark) and the expression of each CD markers on the cells was calculated based on the percentage and mean fluorescence intensity (MFI). |
Upstream tips |
Each cell type was single cell suspended and, incubated in FACS buffer containing pre-conjugated antibodies (see supplementary Table 2) for 20 min on ice. |
Protocol tips |
. Following incubation, cells were washed twice with FACS buffer. |
Downstream tips |
All the flow cytometry performed using a Cell Lab Quanta SCMPL. The data were analyzed using Kaluza®1.2 software (Beckman Coulter, Denmark) and the expression of each CD markers on the cells was calculated based on the percentage and mean fluorescence intensity (MFI). |
Publication protocol
Cells were profiled for surface markers to identify their immune-phenotype. Each cell type was single cell suspended and, incubated in FACS buffer containing pre-conjugated antibodies (see supplementary Table 2) for 20 min on ice. Following incubation, cells were washed twice with FACS buffer. All the flow cytometry performed using a Cell Lab Quanta SCMPL. The data were analyzed using Kaluza®1.2 software (Beckman Coulter, Denmark) and the expression of each CD markers on the cells was calculated based on the percentage and mean fluorescence intensity (MFI).
Full paper
Login or
join for free to view the full paper.
Reviews
Purified anti-mouse CD105 Antibody from BioLegend has not yet been reviewed for this experiment
We'd love it if you would be the first to write a review!
Discussion
Start your discussion
Share your thoughts or question with experts in your field
Start a discussion
Papers
Check out relevant papers found by Labettor's AI that are relevant for performing Flow cytometry Anti-bodies Mouse - CD105 using Purified anti-mouse CD105 Antibody from BioLegend.
Videos
Check out videos that might be relevant for performing Flow cytometry Anti-bodies Mouse - CD105 using Purified anti-mouse CD105 Antibody from BioLegend. Please note that these videos are representative and steps or experiment specific processes must be kept in mind to expect desired results.
We haven't found any additional videos for this experiment / product combination yet.