CD14 Monoclonal Antibody (Sa2-8), APC, eBioscience™

Flow cytometry Anti-bodies Mouse - CD14

Experiment
Flow cytometry Anti-bodies Mouse - CD14
Product
CD14 Monoclonal Antibody (Sa2-8), APC, eBioscience™ from eBioscience
Manufacturer
eBioscience

Protocol tips

Upstream tips
Immortal macrophages, primary bone marrow derived macrophages and DCs or splenic DCs (0.5×106) of the indicated genotypes were treated with E.coli LPS and/or oxPAPC for the indicated time points at 37°C.
Protocol tips
Cells were then washed with 1 mL cold PBS and stained for appropriate antibodies on ice for 20 to 30 min. 2% mouse serum or rat serum were used as the blocking reagent to reduce non-specific binding of the antibodies. The stained cells were then washed with 1ml cold PBS and resuspended in 200 μL PBS.
Downstream tips
Staining of the surface receptors was analyzed with BD FACSCanto II.

Publication protocol

mmortal macrophages, primary bone marrow derived macrophages and DCs or splenic DCs (0.5×106) of the indicated genotypes were treated with E.coli LPS and/or oxPAPC for the indicated time points at 37°C. Cells were then washed with 1 mL cold PBS and stained for appropriate antibodies on ice for 20 to 30 min. 2% mouse serum or rat serum were used as the blocking reagent to reduce non-specific binding of the antibodies. The stained cells were then washed with 1ml cold PBS and resuspended in 200 μL PBS. Staining of the surface receptors was analyzed with BD FACSCanto II. The mean fluorescence intensity (MFI) of CD14 and TLR4 from unstimulated or stimulated cells were recorded. The percentage of surface receptor staining at indicated time points, which is the ratio of the MFI values measured from the stimulated cells to those measured from the unstimulated cells, was plotted to reflect the efficiency of receptor endocytosis. For measuring the extent of TLR4/MD-2 dimerization, the percentage of TLR4/MD2 dimer was calculated by 100%-the percentage of TLR4/MD-2 monomer. The percentage of the TLR4/MD-2 monomer was determined by the ratio of the MFI values (obtained from MTS510 antibody staining) of the stimulated cells to those of the unstimulated cells.

Full paper   Login or join for free to view the full paper.

Reviews

CD14 Monoclonal Antibody (Sa2-8), APC, eBioscience™ from eBioscience has not yet been reviewed for this experiment

We'd love it if you would be the first to write a review!

Discussion

Start your discussion

Share your thoughts or question with experts in your field

Start a discussion

Papers

Check out relevant papers found by Labettor's AI that are relevant for performing Flow cytometry Anti-bodies Mouse - CD14 using CD14 Monoclonal Antibody (Sa2-8), APC, eBioscience™ from eBioscience.

View full paper   Login or join for free to view the full paper.

Manufacturer protocol

Download the product protocol from eBioscience for CD14 Monoclonal Antibody (Sa2-8), APC, eBioscience™ below.

Download PDF Download manufacturer protocol

Videos

Check out videos that might be relevant for performing Flow cytometry Anti-bodies Mouse - CD14 using CD14 Monoclonal Antibody (Sa2-8), APC, eBioscience™ from eBioscience. Please note that these videos are representative and steps or experiment specific processes must be kept in mind to expect desired results.

We haven't found any additional videos for this experiment / product combination yet.

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms