PE-Cy™7 Rat anti-Mouse CD117

Flow cytometry Anti-bodies Mouse - CD117/c-kit

Experiment
Flow cytometry Anti-bodies Mouse - CD117/c-kit
Product
PE-Cy™7 Rat anti-Mouse CD117 from BD Biosciences
Manufacturer
BD Biosciences

Protocol tips

Upstream tips
Samples were isolated from mouse tissues or tumors as above or from trypsinized from tissue culture samples.
Protocol tips
Unstained samples and samples with antibody IgG controls were run in parallel. Additionally, color compensation for each fluorochrome was evaluated using IgG compensation beads (552843, BD Pharmingen) and ArC compensation beads (A10346, Invitrogen) with appropriate fluorescent marker controls.
Downstream tips
Flow cytometry was performed in the Stanford Flow Cytometry Core Facility using the BD Aria II (sorting) or BD LSR.II (analysis).

Publication protocol

Flow cytometry was performed in the Stanford Flow Cytometry Core Facility using the BD Aria II (sorting) or BD LSR.II (analysis). Samples were isolated from mouse tissues or tumors as above or from trypsinized from tissue culture samples. Cells were blocked with CD16/CD32 Mouse Fc Block (553142, BD Pharmingen) for 30 minutes, then labeled with anti-Flk-1:PE, anti-c-Kit:PE-Cy7, anti-CD45: APC-Cy7, and as indicated, anti-CD31: FITC. Unstained samples and samples with antibody IgG controls were run in parallel. Additionally, color compensation for each fluorochrome was evaluated using IgG compensation beads (552843, BD Pharmingen) and ArC compensation beads (A10346, Invitrogen) with appropriate fluorescent marker controls. Once lasers were tuned and color compensation was set, at least 100,000 cells per sample were run, except for the adipose tissue samples which were run at 50,000 cells per sample. Gating was initially applied to isolate single cell populations of viable cells, then additional gating was used to select for the appropriate subpopulations (Flk-1+/c-Kit+/CD45-). Flow cytometric analysis was performed using FlowJo Software (TreeStar, Inc., Ashland, OR). For the flow cytometry sorting of live cells, the same staining process was used as above. Once subpopulations of single, viable cells were gated on Flk1+, c-Kit+, and CD45- and subsequently isolated, they were then collected in an eppendorf tube with 500 μL of mouse endothelial media (M1168, Cell Biologics, Chicago, IL) supplemented with the growth factor kit (VEGF, EGF, heparin, hydrocortisone, and L-Glumatine) and 10% FBS and managed as in vitro cultures as described below.

Full paper   Login or join for free to view the full paper.

Reviews

PE-Cy™7 Rat anti-Mouse CD117 from BD Biosciences has not yet been reviewed for this experiment

We'd love it if you would be the first to write a review!

Discussion

Start your discussion

Share your thoughts or question with experts in your field

Start a discussion

Papers

Check out relevant papers found by Labettor's AI that are relevant for performing Flow cytometry Anti-bodies Mouse - CD117/c-kit using PE-Cy™7 Rat anti-Mouse CD117 from BD Biosciences.

View full paper   Login or join for free to view the full paper.

Manufacturer protocol

Download the product protocol from BD Biosciences for PE-Cy™7 Rat anti-Mouse CD117 below.

Download PDF Download manufacturer protocol

Videos

Check out videos that might be relevant for performing Flow cytometry Anti-bodies Mouse - CD117/c-kit using PE-Cy™7 Rat anti-Mouse CD117 from BD Biosciences. Please note that these videos are representative and steps or experiment specific processes must be kept in mind to expect desired results.

We haven't found any additional videos for this experiment / product combination yet.

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms