Protocol tips
Upstream tips |
Protocol tips |
Downstream tips |
|
- 1X DCFH-DA/media solution contains 5% methanol. For cells that are sensitive to methanol,
we recommend instead preparing a 0.1X (100 µM) solution of DCFH-DA in cell culture media. |
- Due to light-induced auto-oxidation, DCFH-DA solutions at any concentration must be
protected from light. |
Protocol tips |
- 1X DCFH-DA/media solution contains 5% methanol. For cells that are sensitive to methanol,
we recommend instead preparing a 0.1X (100 µM) solution of DCFH-DA in cell culture media. |
Downstream tips |
- Due to light-induced auto-oxidation, DCFH-DA solutions at any concentration must be
protected from light. |
Publication protocol
Intracellular ROS generation was measured with an OxiSelect ROS Assay Kit (CELL BIOLABS, San Diego, CA) according to the manufacturer's instructions. The cell membrane-permeable fluorescent dye 2’,7’-dichlorofluorescein diacetate (DCFH-DA) was added to cells. DCFH-DA is converted to the impermeable nonfluorescent compound DCFH by intracellular esterases. Highly fluorescent DCF is produced by oxidation of DCFH by ROS. The fluorescence intensity of DCF inside the cells was measured using an EnVision plate reader. Triplicate wells were analyzed in each assay.
Full paper
Login or
join for free to view the full paper.
Reviews
OxiSelect™ Intracellular ROS Assay Kit (Green Fluorescence) from Cell Biolabs has not yet been reviewed for this experiment
We'd love it if you would be the first to write a review!
Discussion
Start your discussion
Share your thoughts or question with experts in your field
Start a discussion
Papers
Check out relevant papers found by Labettor's AI that are relevant for performing ROS assay cell type - PLHC-1, SK-HEP-1, Hep3b, HepG2 human hepatocellular carcinoma using OxiSelect™ Intracellular ROS Assay Kit (Green Fluorescence) from Cell Biolabs.
Paper title
Cancer stem-like sphere cells induced from de-differentiated hepatocellular carcinoma-derived cell lines possess the resistance to anti-cancer drugs
Manufacturer protocol
Download the product protocol from Cell Biolabs for OxiSelect™ Intracellular ROS Assay Kit (Green Fluorescence) below.
Download manufacturer protocol
Videos
Check out videos that might be relevant for performing ROS assay cell type - PLHC-1, SK-HEP-1, Hep3b, HepG2 human hepatocellular carcinoma using OxiSelect™ Intracellular ROS Assay Kit (Green Fluorescence) from Cell Biolabs. Please note that these videos are representative and steps or experiment specific processes must be kept in mind to expect desired results.
We haven't found any additional videos for this experiment / product combination yet.