Human IL-6R alpha Antibody

Flow cytometry Anti-bodies Human - CD126/IL-6Ralpha

Experiment
Flow cytometry Anti-bodies Human - CD126/IL-6Ralpha
Product
Human IL-6R alpha Antibody from R&D Systems
Manufacturer
R&D Systems

Protocol tips

Protocol tips
>20 × 105 disaggregated sphere cells were stained with a stem cell‐specific antibody panel and analysed on a BDTM LSR II flow cytometer. To a volume of 100 μL cell suspension, 5 μL antibody mix was added, mixed and incubated for 20 minutes at 4°C in the dark and washed twice with 250 μL DPBS or FACS buffer.

Publication protocol

"1. Cell count
The expression of stem cell markers was assessed by flow cytometry. Cells were harvested and counted in a volume of 100 μL on a BD LSR II flow cytometer (Becton Dickinson, San Diego, CA, USA) using TruCountTM tubes (BD Biosciences, San José, CA, USA). The absolute count of the cell population was obtained using FlowJo Analysis Software V10 (Tree Star, Ashland, OR, USA).

2. Instrumentation
A flow cytometer (LSR II; BD Biosciences) equipped with Diva V8.0 software was used for 9‐color phenotypic analysis. Laser alignment (405‐nm violet laser, 488‐nm blue laser, 640‐nm red laser) was verified with beads prior to running tumor cell samples. The nine colors used in the analysis were compensated twice to account for spectral overlap emitted by the fluorochromes within each laser as well as across the lasers using a semi‐automated as well as a manual process by the application of compensation beads (BD Biosciences) coated with anti‐human Ig antibodies. The beads were incubated with each individual antibody used in the nine‐color panel for 15 minutes at room temperature. Unstained and stained beads were run individually, 5000 events were recorded, and data were imported into Diva V8.0 software including compensation matrices for automatic as well as additional manual compensation.

3. 9‐color tumor cell labeling
For the evaluation of the stem cell phenotype of the gliomaspheres, >20 × 105 disaggregated sphere cells were stained with a stem cell‐specific antibody panel and analysed on a BDTM LSR II flow cytometer. To a volume of 100 μL cell suspension, 5 μL antibody mix was added, mixed and incubated for 20 minutes at 4°C in the dark and washed twice with 250 μL DPBS or FACS buffer. For the full set of antibodies see Table S1. 7‐AAD was used as viability dye. Additionally, unstained controls as well as appropriate human isotype controls were added to the panel according to the manufacturer's recommendations."

Full paper   Login or join for free to view the full paper.

Reviews

Human IL-6R alpha Antibody from R&D Systems has not yet been reviewed for this experiment

We'd love it if you would be the first to write a review!

Discussion

Start your discussion

Share your thoughts or question with experts in your field

Start a discussion

Papers

Check out relevant papers found by Labettor's AI that are relevant for performing Flow cytometry Anti-bodies Human - CD126/IL-6Ralpha using Human IL-6R alpha Antibody from R&D Systems.

View full paper   Login or join for free to view the full paper.

Manufacturer protocol

Download the product protocol from R&D Systems for Human IL-6R alpha Antibody below.

Download PDF Download manufacturer protocol

Videos

Check out videos that might be relevant for performing Flow cytometry Anti-bodies Human - CD126/IL-6Ralpha using Human IL-6R alpha Antibody from R&D Systems. Please note that these videos are representative and steps or experiment specific processes must be kept in mind to expect desired results.

We haven't found any additional videos for this experiment / product combination yet.

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms