Cells were stained with a fixable Live/Dead dye (ThermoFisher Scientific) concurrently with saturating concentrations of surface mAbs (Table S2) in a buffer containing 50%ABrilliant Violet Buffer (BD Bioscience) and 50%APBS for 30min at 4°C. Once stained PBMC and IHL were fixed and permeabilised, where necessary, with either Cytofix/Cytoperm (BD Bioscience), or with the FoxP3 Buffer Kit (BD Bioscience) according to manufacturer’s instructions. |
All samples were acquired in a 0.1% saponin buffer on an X20FortessaASORP (BD Biosciences) and analysed in FlowJo (TreeStar). |
Protocol tips |
Cells were stained with a fixable Live/Dead dye (ThermoFisher Scientific) concurrently with saturating concentrations of surface mAbs (Table S2) in a buffer containing 50%ABrilliant Violet Buffer (BD Bioscience) and 50%APBS for 30min at 4°C. Once stained PBMC and IHL were fixed and permeabilised, where necessary, with either Cytofix/Cytoperm (BD Bioscience), or with the FoxP3 Buffer Kit (BD Bioscience) according to manufacturer’s instructions. |
Downstream tips |
All samples were acquired in a 0.1% saponin buffer on an X20FortessaASORP (BD Biosciences) and analysed in FlowJo (TreeStar). |
Publication protocol
Cells were stained with a fixable Live/Dead dye (ThermoFisher Scientific) concurrently with saturating concentrations of surface mAbs (Table S2) in a buffer containing 50%ABrilliant Violet Buffer (BD Bioscience) and 50%APBS for 30min at 4°C. Once stained PBMC and IHL were fixed and permeabilised, where necessary, with either Cytofix/Cytoperm (BD Bioscience), or with the FoxP3 Buffer Kit (BD Bioscience) according to manufacturer’s instructions. Intracellular proteins were detected with saturating concentrations of mAbs for 30mins at 4°C in either a 0.1% saponin (SigmaAAldrich) buffer containing 10% FBS (SigmaAAldrich) or 1x PBS. All samples were acquired in a 0.1% saponin buffer on an X20FortessaASORP (BD Biosciences) and analysed in FlowJo (TreeStar).
Full paper
Login or
join for free to view the full paper.
Reviews
FITC anti-human CD20 Antibody from BioLegend has not yet been reviewed for this experiment
We'd love it if you would be the first to write a review!
Discussion
Start your discussion
Share your thoughts or question with experts in your field
Start a discussion
Papers
Check out relevant papers found by Labettor's AI that are relevant for performing Flow cytometry Anti-bodies Human - CD20 using FITC anti-human CD20 Antibody from BioLegend.
Videos
Check out videos that might be relevant for performing Flow cytometry Anti-bodies Human - CD20 using FITC anti-human CD20 Antibody from BioLegend. Please note that these videos are representative and steps or experiment specific processes must be kept in mind to expect desired results.
We haven't found any additional videos for this experiment / product combination yet.