Protocol tips
Upstream tips |
Protocol tips |
Downstream tips |
|
Samples were processed using a standard lyse/wash surface staining procedure with FACS Lyse solution according to the manufacturer's protocol (BDIS,www.bdbiosciences.com). Caltag Fix and Perm reagent kit (Invitrogen, Caltag, Catalogue No. GAS‐004) was used for intracellular staining. The 1 × 106 leukocytes in 100 μL of sample were stained with an appropriate volume of antibodies in each tube. |
All samples were analyzed using the Euroflow 8‐color immunophenotyping panel (Table 1) on the FACSCantoII cytometer (Becton Dickinson, San Jose, California). Instrument set‐up and compensation matrix was established using CS&T and FACS Comp beads as per the manufacturer's recommendations. |
Protocol tips |
Samples were processed using a standard lyse/wash surface staining procedure with FACS Lyse solution according to the manufacturer's protocol (BDIS,www.bdbiosciences.com). Caltag Fix and Perm reagent kit (Invitrogen, Caltag, Catalogue No. GAS‐004) was used for intracellular staining. The 1 × 106 leukocytes in 100 μL of sample were stained with an appropriate volume of antibodies in each tube. |
Downstream tips |
All samples were analyzed using the Euroflow 8‐color immunophenotyping panel (Table 1) on the FACSCantoII cytometer (Becton Dickinson, San Jose, California). Instrument set‐up and compensation matrix was established using CS&T and FACS Comp beads as per the manufacturer's recommendations. |
Publication protocol
FC immunophenotyping studies were performed on BM or PB samples from patients with suspected NK‐cell malignancies. All samples were analyzed using the Euroflow 8‐color immunophenotyping panel (Table 1) on the FACSCantoII cytometer (Becton Dickinson, San Jose, California). Instrument set‐up and compensation matrix was established using CS&T and FACS Comp beads as per the manufacturer's recommendations. Samples were processed using a standard lyse/wash surface staining procedure with FACS Lyse solution according to the manufacturer's protocol (BDIS,www.bdbiosciences.com). Caltag Fix and Perm reagent kit (Invitrogen, Caltag, Catalogue No. GAS‐004) was used for intracellular staining. The 1 × 106 leukocytes in 100 μL of sample were stained with an appropriate volume of antibodies in each tube.
Full paper
Login or
join for free to view the full paper.
Reviews
PE Mouse Anti-Human CD26 Clone L272 from BD Biosciences has not yet been reviewed for this experiment
We'd love it if you would be the first to write a review!
Discussion
Start your discussion
Share your thoughts or question with experts in your field
Start a discussion
Papers
Check out relevant papers found by Labettor's AI that are relevant for performing Flow cytometry Anti-bodies Human - CD26 using PE Mouse Anti-Human CD26 Clone L272 from BD Biosciences.
Videos
Check out videos that might be relevant for performing Flow cytometry Anti-bodies Human - CD26 using PE Mouse Anti-Human CD26 Clone L272 from BD Biosciences. Please note that these videos are representative and steps or experiment specific processes must be kept in mind to expect desired results.
We haven't found any additional videos for this experiment / product combination yet.