APC-H7 Mouse Anti-Human CD43

Flow cytometry Anti-bodies Human - CD43

Experiment
Flow cytometry Anti-bodies Human - CD43
Product
APC-H7 Mouse Anti-Human CD43 from BD Biosciences
Manufacturer
BD Biosciences

Protocol tips

Downstream tips
Immediately after sample preparation, a minimum of 5 × 104 events/sample aliquot was collected using a FACSCanto II flow cytometer equipped with the FACSDiva™ software program (BD Biosciences, USA). For data analysis, the Infinicyt™ 1.7 software (Cytognos SL, Salamanca, Spain) was employed.

Publication protocol

BM samples were collected in EDTA anticoagulant while aspirates and biopsy samples were placed in saline. Staining of surface markers followed by erythrocyte lysis was performed according to well‐established protocols 12. The following panel of eight‐color combinations of monoclonal antibodies was used for the diagnosis of BCL: CD20+CD4/CD45/CD8+Igλ/CD56+Igκ/CD5/CD19/CD3/CD38 (lymphoid screening tube), CD20/CD45/CD23/CD10/CD200/CD19/CD79b/CD43, CD20/CD45/CD31/LAIR‐1/CD11c/CD19/sIgM/CD81,CD20/CD45/CD103/CD95/CD22/CD19/CXCR5/CD49d, and CD20/CD45/CD62L/CD39/X/CD19/CD27/X. The fluorochrome order was: pacific blue (PacB), pacific orange (PacO), fluorescein isothiocyanate (FITC), phycoerythrin (PE), peridinin chlorophyll protein (PerCP‐Cy5.5), phycoerythrin/Cy7 (PE‐Cy7), allophycocyanin (APC), and allophycocyanin/Cy7 (APC‐Cy7) and “X” means no added marker. Details about technical information on CD39, CD43, CD81, and CD95 reagents can be observed in Table 1. Immediately after sample preparation, a minimum of 5 × 104 events/sample aliquot was collected using a FACSCanto II flow cytometer equipped with the FACSDiva™ software program (BD Biosciences, USA). For data analysis, the Infinicyt™ 1.7 software (Cytognos SL, Salamanca, Spain) was employed. Merge and calculation of flow cytometric data corresponding to each individual sample was performed as previously described 13, 14, using the Infinicyt™ 1.7 software program (Cytognos SL, Salamanca, Spain) after gating on CD19+ and CD20+ lymphoma cells. Whenever identified, residual normal B cells were excluded from analysis. Then, the mean fluorescence intensity (MFI) values of each marker for each individual were obtained and the median value of the MFI of groups with the same neoplasm was calculated. In addition, comparison among groups was performed by multivariate analysis, such as the principal component analysis (PCA), using information on the markers from the eight‐color panel, with the exception of immunoglobulin light chain kappa (Igκ) and lambda (Igλ).

Full paper   Login or join for free to view the full paper.

Reviews

APC-H7 Mouse Anti-Human CD43 from BD Biosciences has not yet been reviewed for this experiment

We'd love it if you would be the first to write a review!

Discussion

Start your discussion

Share your thoughts or question with experts in your field

Start a discussion

Papers

Check out relevant papers found by Labettor's AI that are relevant for performing Flow cytometry Anti-bodies Human - CD43 using APC-H7 Mouse Anti-Human CD43 from BD Biosciences.

View full paper   Login or join for free to view the full paper.

Manufacturer protocol

Download the product protocol from BD Biosciences for APC-H7 Mouse Anti-Human CD43 below.

Download PDF Download manufacturer protocol

Videos

Check out videos that might be relevant for performing Flow cytometry Anti-bodies Human - CD43 using APC-H7 Mouse Anti-Human CD43 from BD Biosciences. Please note that these videos are representative and steps or experiment specific processes must be kept in mind to expect desired results.

We haven't found any additional videos for this experiment / product combination yet.

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms