PE anti-human CD96 (TACTILE) Antibody

Flow cytometry Anti-bodies Human - CD96

Experiment
Flow cytometry Anti-bodies Human - CD96
Product
PE anti-human CD96 (TACTILE) Antibody from BioLegend
Manufacturer
BioLegend

Protocol tips

Protocol tips
Cells were stained with Annexin V-fluorescein isothiocyanate (FITC)/propidium iodide (PI) (BD Pharmingen, San Diego, CA, USA) to detect the apoptosis state in accordance with the manufacturer specifications.
Downstream tips
The cells (1 × 106) were collected and resuspended in 100 μl Cell Staining Buffer, the antibody was added and incubated at 4 °C for 15 min, washed again with cell staining buffer one time, and then subject to the apoptosis assay. To exclude non-viable cells, cells were stained with 7AAD before flow cytometry (BD Versa, San Diego, CA, USA) analysis for antigen detecting.

Publication protocol

Cell cycle, cell apoptosis, and cell surface antigens were detected using flow cytometry. In brief, 48 h after treatment of KG-1, Kasumi-1, KG-1a, TF-1, or primary cells, the cell density was adjusted according to the cell viability assay and prepared for cell cycle analysis as described in our previous report [17]. Cells were stained with Annexin V-fluorescein isothiocyanate (FITC)/propidium iodide (PI) (BD Pharmingen, San Diego, CA, USA) to detect the apoptosis state in accordance with the manufacturer specifications. The CD34+/CD38− population (Kasumi-1 cells) or CD34+/CD38−/CD96+ population (KG-1 cells) was obtained by incubating with CD34–FITC (Biolegend, San Diego, CA USA), CD38–R-phycoerythrin cyanine7 (CD38–PE-Cy™7; Biolegend), and CD96–R-phycoerythrin (CD96-PE; Biolegend) in Cell Staining Buffer (Biolegend); Annexin V–FITC and CD38–PE-Cy™7 were used for KG-1, KG-a, and TF-1 cells, and CD34–APC was also added for primary cells. The procedure was as follows: The cells (1 × 106) were collected and resuspended in 100 μl Cell Staining Buffer, the antibody was added and incubated at 4 °C for 15 min, washed again with cell staining buffer one time, and then subject to the apoptosis assay. To exclude non-viable cells, cells were stained with 7AAD before flow cytometry (BD Versa, San Diego, CA, USA) analysis for antigen detecting.

Full paper   Login or join for free to view the full paper.

Reviews

PE anti-human CD96 (TACTILE) Antibody from BioLegend has not yet been reviewed for this experiment

We'd love it if you would be the first to write a review!

Discussion

Start your discussion

Share your thoughts or question with experts in your field

Start a discussion

Papers

Check out relevant papers found by Labettor's AI that are relevant for performing Flow cytometry Anti-bodies Human - CD96 using PE anti-human CD96 (TACTILE) Antibody from BioLegend.

View full paper   Login or join for free to view the full paper.

Manufacturer protocol

Download the product protocol from BioLegend for PE anti-human CD96 (TACTILE) Antibody below.

Download PDF Download manufacturer protocol

Videos

Check out videos that might be relevant for performing Flow cytometry Anti-bodies Human - CD96 using PE anti-human CD96 (TACTILE) Antibody from BioLegend. Please note that these videos are representative and steps or experiment specific processes must be kept in mind to expect desired results.

We haven't found any additional videos for this experiment / product combination yet.

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms