HincII (HindII) (10 U/µL)

Restriction Enzymes HincII / HindII

Experiment
Restriction Enzymes HincII / HindII
Product
HincII (HindII) (10 U/µL) from Thermo Fisher Scientific
Manufacturer
Thermo Fisher Scientific

Protocol tips

Protocol tips
A total of 5 μg of mitochondrial nucleic acid was digested according to the manufacturer’s recommendation with BclI or HincII (both from Thermo Scientific) and run on a 0.4% agarose gel in 1× TBE until the fragments of interest had migrated 10 cm into the gel. The gel slab was rotated 90°, and a 0.95% agarose gel was cast around it.

Publication protocol

A total of 5 μg of mitochondrial nucleic acid was digested according to the manufacturer’s recommendation with BclI or HincII (both from Thermo Scientific) and run on a 0.4% agarose gel in 1× TBE until the fragments of interest had migrated 10 cm into the gel. The gel slab was rotated 90°, and a 0.95% agarose gel was cast around it. The second dimension was run until the fragment of interest had migrated ∼10 cm. For long-range 2D AGEs, 5 μg of mitochondrial nucleic acids was digested with FastDigest BamHI or PvuII (Thermo Scientific), which cut mtDNA only once, and run on a 0.28% agarose gel in 1× TBE until the linearized mtDNA fragment had migrated 10 cm into the gel. The gel slab was rotated 90°, and a 0.58% agarose gel was cast around it. The second dimension was run at 2.6 V/cm until the fragment of interest had migrated ∼10 cm from the top. Southern blotting was performed by using the standard procedure, and the nucleic acid hybridization was performed by using a PCR probe spanning nucleotides 14,783–15,333 (Cytb) of the mouse mtDNA and 4,470–5,511 (ND2) or 35–611 (NCR) of the human mtDNA. Probes were labeled by using a Rediprime II random prime labeling kit (GE Healthcare) and [α-32P]dCTP (3,000 Ci/mmol; PerkinElmer). The autoradiographs were exposed on a Kodak MS film (Sigma-Aldrich) or were captured on a Kodak storage phosphor screen SO230 and detected by using Molecular Imager FX (BioRad).

Full paper   Login or join for free to view the full paper.

Reviews

HincII (HindII) (10 U/µL) from Thermo Fisher Scientific has not yet been reviewed for this experiment

We'd love it if you would be the first to write a review!

Discussion

Start your discussion

Share your thoughts or question with experts in your field

Start a discussion

Papers

Check out relevant papers found by Labettor's AI that are relevant for performing Restriction Enzymes HincII / HindII using HincII (HindII) (10 U/µL) from Thermo Fisher Scientific.

View full paper   Login or join for free to view the full paper.

Manufacturer protocol

Download the product protocol from Thermo Fisher Scientific for HincII (HindII) (10 U/µL) below.

Download PDF Download manufacturer protocol

Videos

Check out videos that might be relevant for performing Restriction Enzymes HincII / HindII using HincII (HindII) (10 U/µL) from Thermo Fisher Scientific. Please note that these videos are representative and steps or experiment specific processes must be kept in mind to expect desired results.

We haven't found any additional videos for this experiment / product combination yet.

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms