Cell Counting Kit-8

Cell cytotoxicity / Proliferation assay cell type - MDA-MB-231 breast adenocarcenoma

Experiment
Cell cytotoxicity / Proliferation assay cell type - MDA-MB-231 breast adenocarcenoma
Product
Cell Counting Kit-8 from Dojindo
Manufacturer
Dojindo

Protocol tips

Protocol tips
- Plate was incubated at 37ºC for 4 hours and then quantifiably measured at a wavelength of 570 nm.

Publication protocol

MDA-MB-231 cells were plated at density of 1,000 cells/well in a 96-well plate. Then, the indicated concentration of DPPA was added 24 hours later, and each concentration was tested in quadruplicate. Cell viability and cell proliferation were evaluated using the Cell Counting Kit-8 (CCK8) assay. The CCK8 reagent was added at the indicated time, and the plate was incubated at 37ºC for 4 hours and then quantifiably measured at a wavelength of 570 nm. The data were obtained from three independent experiments. A colony formation assay was also used to detect cell proliferation. Briefly, MDA-MB-231 cells (3,000 cells/well) and 4T1 cells (1,500 cells/well) were seeded into 6-well plates. Then, the indicated concentrations of DMSO and DPPA were added into the wells 24 hours later. The colonies were fixed and stained after 7 days of growth. The effect of each treatment was assessed from three replicates and three independent experiments.

Full paper   Login or join for free to view the full paper.

Reviews

Cell Counting Kit-8 from Dojindo has not yet been reviewed for this experiment

We'd love it if you would be the first to write a review!

Discussion

Start your discussion

Share your thoughts or question with experts in your field

Start a discussion

Papers

Check out relevant papers found by Labettor's AI that are relevant for performing Cell cytotoxicity / Proliferation assay cell type - MDA-MB-231 breast adenocarcenoma using Cell Counting Kit-8 from Dojindo.

Paper title
Dipalmitoylphosphatidic acid inhibits tumor growth in triple-negative breast cancer
Full paper
Login or join for free to view the full paper.

Manufacturer protocol

Download the product protocol from Dojindo for Cell Counting Kit-8 below.

Download PDF Download manufacturer protocol

Videos

Check out videos that might be relevant for performing Cell cytotoxicity / Proliferation assay cell type - MDA-MB-231 breast adenocarcenoma using Cell Counting Kit-8 from Dojindo. Please note that these videos are representative and steps or experiment specific processes must be kept in mind to expect desired results.

We haven't found any additional videos for this experiment / product combination yet.

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms