Cell cytotoxicity assays measure the ability of certain compounds or chemical mediators to reduce the viability of the cells. The term cell cytotoxicity assay can sometimes be used interchangeably with cell proliferation assay. Healthy living cells can be identified by the use of formazan dyes, protease biomarkers or by measuring ATP content. The formazan dyes are chromogenic products formed by the reduction of tetrazolium salts by dehydrogenases, such as lactate dehydrogenase (LDH) and reductases that are released during cell death. Common tetrazolium salts include INT, MTT, MTS and XTT. Cell cytotoxicity can also be measured by using the SRB and WST-1 assays. These assays can usually be used in a high-throughput fashion and can be quantitated by measuring absorbance, colorimetry or luminescence. All these assays require similar numbers of cell plating at the initiation, a time course of treatment with the cytotoxic agent and at least triplicates for each condition at every point of analysis. Cell shrinkage, plasma membrane blebbing, cell detachment, externalization of phosphatidylserine, nuclear condensation and ultimately DNA fragmentation are well-described features of apoptosis. The assays that rely on cell membrane integrity for their function, may not be able to quantify early apoptosis. Therefore, in order to distinguish early apoptotic vs. late apoptotic or necrotic cells, additional flow cytometry techniques can be used. A combination of Annexin V and PI (propidium iodide) can be used to distinguish early (Annexin V+/PI-) and late apoptotic (Annexin V+/PI+) cells. Sometimes, caspase assays are used in order to differentiate the stages of apoptosis.
Get tips on using FlexiTube GeneSolution GS27279 for Tnfrsf12a to perform siRNA / miRNA gene silencing Mouse - B16-BL6 FN14/Tnfrsf12a
A gross majority of classical apoptotic attributes can be quantitatively examined by flow cytometry, the preferred platform for rapid assessment of multiple cellular attributes at a single-cell level. However, sample preparation for such flow cytometry-based techniques could be challenging. Cell harvesting by trypsinization, mechanical or enzymatic cell disaggregation from tissues, extensive centrifugation steps, may all lead to preferential loss of apoptotic cells. To overcome this strictly follow manufacturers instruction of the detection kit.
Cell Invasion or Cell Migration assays are technically challenging to set up as the gradient between the two compartments equilibrates in time during the assay. It is also problematic to view cells and for cells to migrate through a non-physiologic polycarbonate or polypropylene filter. Care must be taken while loading the well with cells to form a single cell suspension. Precaution must be taken while trypsinization (under-trypsinization can lead to cell clumping while over-trypsinization could strip off adhesion molecules necessary for migration). This leads to difficulty in getting significant results, when only small numbers of cells cross the filter or when the distribution and/or staining of the cells is uneven.
Get tips on using Lipofectamine® 2000 Transfection Reagent to perform siRNA / RNAi /miRNA transfection Mouse - HeLa cells Lipofectamine
Get tips on using SurePrint Human miRNA Microarrays to perform Microarray Human - Endometrial stromal cells miRNA-expression array (labelled)
Get tips on using 3D-Gene® Mouse miRNA Oligo chip (ver.21) to perform Microarray Gene expression arrays - Mouse liver tissue Cyanine-3-CTP
Get tips on using MISSION® esiRNA_esiRNA targeting mouse Lrp5 (esiRNA1) to perform siRNA / miRNA gene silencing Mouse - MLO‐Y4 Lrp5
Get tips on using MISSION® esiRNA_esiRNA targeting mouse Lrp6 (esiRNA1) to perform siRNA / miRNA gene silencing Mouse - MLO‐Y4 Lrp6
Fill out your contact details and receive price quotes in your Inbox
Outsource experiment