Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).
Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).
ROS has a very short half-lives in biological environment as they are influenced by exposure to ambient oxygen. As it is highly reactive and hard to measure care should be taken to ensure the stability of the sample during isolation, preparation, storage, and analysis.
Get tips on using VENTANA anti-MSH2 (G219-1129) Mouse Monoclonal Primary Antibody to perform Immunohistochemistry Human - MSH2
Get tips on using Purified Mouse Anti-Human MLH1 Clone G168-728 (RUO) to perform Immunohistochemistry Human - MLH1
Get tips on using Monoclonal Mouse Anti-Human Androgen Receptor (Concentrate) Clone AR441 to perform Immunohistochemistry Human - AR
Get tips on using Monoclonal Mouse Anti-Human Cytokeratin 20 (Concentrate) Clone Ks20.8 to perform Immunohistochemistry Human - CK20
Get tips on using Purified Mouse Anti-IKKγ Clone 54/IKKγ/NEMO (RUO) to perform Western blotting IKKgamma
Get tips on using Human/Mouse/Rat Phospho-Akt (S473) Pan Specific Antibody to perform Western blotting AKT
Fill out your contact details and receive price quotes in your Inbox
Outsource experiment