Flowcytometry CD3 Mouse / IgG1, kappa

- Found 2407 results

Get tips on using GM-CSF Mouse ELISA Kit to perform ELISA Mouse - GM-CSF

Products Thermo Fisher Scientific GM-CSF Mouse ELISA Kit

Get tips on using Mouse GM-CSF DuoSet ELISA to perform ELISA Mouse - GM-CSF

Products R&D Systems Mouse GM-CSF DuoSet ELISA

Get tips on using Mouse Dkk-1 ELISA Kit to perform ELISA Mouse - Dkk-1

Products Sigma-Aldrich Mouse Dkk-1 ELISA Kit

Get tips on using Mouse BMP2 ELISA Kit (ab119582) to perform ELISA Mouse - BMP-2

Products Abcam Mouse BMP2 ELISA Kit (ab119582)

Get tips on using Mouse SDF1 ELISA Kit (ab100741) to perform ELISA Mouse - SDF-1/CXCL12

Products Abcam Mouse SDF1 ELISA Kit (ab100741)

Get tips on using Purified Rat Anti-Mouse CD24 Clone M1/69 (RUO) to perform Immunohistochemistry Mouse - CD24

Products BD Biosciences Purified Rat Anti-Mouse CD24 Clone M1/69 (RUO)

Get tips on using Purified Rat Anti-Mouse CD24 Clone M1/69 (RUO) to perform Immunohistochemistry Mouse - CD24

Products BD Biosciences Purified Rat Anti-Mouse CD24 Clone M1/69 (RUO)

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse CD34

DNA-protein interactions are studied by using ChIP. The basic steps in this technique are crosslinking, sonication, immunoprecipitation, and analysis of the immunoprecipitated DNA. During ChIP, if chromatin is under-fragmented or fragments are too large which can lead to the increased background and lower resolution. Shorter cross-linking times (5-10 min) and/or lower formaldehyde concentrations (<1%) may improve shearing efficiency. If Chromatin is over-fragmented, then optimize shearing conditions for each cell type to improve ChIP efficiency. Over-sonication of chromatin may disrupt chromatin integrity and denature antibody epitopes. If you do not see any product or very little product in the input PCR reactions, add 5–10 μg chromatin per IP.

Proteins ChIP Mouse CD4+ T

Get tips on using Tlr4 Mouse siRNA Oligo Duplex to perform siRNA / miRNA gene silencing Mouse - BV2 TLR4

Products OriGene Tlr4 Mouse siRNA Oligo Duplex